Standardisation of data from real-time quantitative PCR methods – evaluation of outliers and comparison of calibration curves

Стандартизация данных методов количественной ПЦР в реальном времени: оценка выбросов и сравнение калибровочных кривых
Malcolm Burns, Gavin Nixon, Carole A. Foy, Neil Harris
2005-12-01

ISO guidelinescalibration curve comparisonmeasurement uncertaintyoutlier detectionreal-time quantitative PCR
BACKGROUND: As real-time quantitative PCR (RT-QPCR) is increasingly being relied upon for the enforcement of legislation and regulations dependent upon the trace detection of DNA, focus has increased on the quality issues related to the technique. Recent work has focused on the identification of factors that contribute towards significant measurement uncertainty in the real-time quantitative PCR technique, through investigation of the experimental design and operating procedure. However, measurement uncertainty contributions made during the data analysis procedure have not been studied in detail. This paper presents two additional approaches for standardising data analysis through the novel application of statistical methods to RT-QPCR, in order to minimise potential uncertainty in results. RESULTS: Experimental data was generated in order to develop the two aspects of data handling and analysis that can contribute towards measurement uncertainty in results. This paper describes preliminary aspects in standardising data through the application of statistical techniques to the area of RT-QPCR. The first aspect concerns the statistical identification and subsequent handling of outlying values arising from RT-QPCR, and discusses the implementation of ISO guidelines in relation to acceptance or rejection of outlying values. The second aspect relates to the development of an objective statistical test for the comparison of calibration curves. CONCLUSION: The preliminary statistical tests for outlying values and comparisons between calibration curves can be applied using basic functions found in standard spreadsheet software. These two aspects emphasise that the comparability of results arising from RT-QPCR needs further refinement and development at the data-handling phase. The implementation of standardised approaches to data analysis should further help minimise variation due to subjective judgements. The aspects described in this paper will help contribute towards the development of a set of best practice guidelines regarding standardising handling and interpretation of data arising from RT-QPCR experiments.
1
Both preliminary procedures can be implemented using basic functions in standard spreadsheet software.
2
It develops statistical procedures for identifying and handling RT-qPCR outliers, including implementation of ISO guidance for accepting or rejecting anomalous values.
3
It proposes an objective statistical test for comparing RT-qPCR calibration curves.
4
Standardized data-analysis methods may reduce variation caused by subjective judgments, although comparability of RT-qPCR results requires further refinement and development.
5
The study addresses measurement uncertainty introduced during RT-qPCR data analysis, complementing prior work on experimental design and operating procedures.

real-time quantitative PCR (RT-QPCR) data and calibration curves

standardisation of data analysis, including statistical identification and handling of outliers and objective comparison of calibration curves to reduce measurement uncertainty

Publication Details
Publication Date
2005-12-01
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Malcolm Burns
Gavin Nixon
Carole A. Foy
Neil Harris
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%