Novel Carbon/PEDOT/PSS-Based Screen-Printed Biosensors for Acetylcholine Neurotransmitter and Acetylcholinesterase Detection in Human Serum

Новые трафаретно-печатные биосенсоры на основе углерода/PEDOT/PSS для определения нейромедиатора ацетилхолина и ацетилхолинэстеразы в сыворотке крови человека
Nashwa H. Ashmawy, Abdulrahman A. Almehizia, Teraze A. Youssef, Abd El‐Galil E. Amr, Mohamed A. Al‐Omar, Ayman H. Kamel
2019-04-18

PEDOT/PSS solid contactacetylcholine biosensorsacetylcholinesterase activityhuman serum analysispotentiometric ion-selective electrodes
New reliable and robust potentiometric ion-selective electrodes were fabricated using poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) as the solid contact between the sensing membrane and electrical substrate for an acetylcholine (ACh) bioassay. A film of PEDOT/PSS was deposited on a solid carbon screen-printed platform made from ceramic substrate. The selective materials used in the ion-selective electrode (ISE) sensor membrane were acetylcholinium tetraphenylborate (ACh/TPB/PEDOT/PSS-ISE) (sensor I) and triacetyl-β-cyclodextrin (β-CD/PEDOT/PSS-ISE) (sensor II). The sensors revealed clear enhanced Nernstian response with a cationic slope 56.4 ± 0.6 and 55.3 ± 1.1 mV/decade toward (ACh+) ions over the dynamic linear range 1.0 × 10−6–1 × 10−3 and 2.0 × 10−6–1.0 × 10−3 M at pH 5 with limits of detection 2.0 × 10−7 and 3.2 × 10−7 M for sensors I and II, respectively. The selectivity behavior of both sensors was also tested and the sensors showed a significant high selectivity toward ACh+ over different common organic and inorganic cations. The stability of the potential response for the solid-contact (SC)/ISEs was evaluated using a chronopotentiometric method and compared with that of electrodes prepared without adding the solid-contact material (PEDOT/PSS). Enhanced accuracy, excellent repeatability, good reproducibility, potential stability, and high selectivity and sensitivity were introduced by these cost-effective sensors. The sensors were also used to measure the activity of acetylcholinesterase (AChE). A linear plot between the initial rate of the hydrolysis of ACh+ substrate and enzyme activity held 5.0 × 10−3–5.2 IU L−1 of AChE enzyme. Application to acetylcholine determination in human serum was done and the results were compared with the standard colorimetric method.
1
Both electrodes exhibited high selectivity for acetylcholine over common organic and inorganic cations, along with improved stability, repeatability, reproducibility, accuracy, and sensitivity.
2
PEDOT/PSS solid-contact layers enabled robust, potentiometric screen-printed carbon electrodes for acetylcholine detection.
3
Sensor I and sensor II achieved linear ranges of 1.0 × 10−6–1 × 10−3 M and 2.0 × 10−6–1.0 × 10−3 M, with detection limits of 2.0 × 10−7 and 3.2 × 10−7 M, respectively.
4
The sensors quantified acetylcholinesterase activity linearly from 5.0 × 10−3 to 5.2 IU L−1 and were applied to acetylcholine determination in human serum, with results compared against a colorimetric method.
5
The two sensors showed near-Nernstian acetylcholine responses of 56.4 ± 0.6 and 55.3 ± 1.1 mV/decade.

PEDOT/PSS-based carbon screen-printed potentiometric ion-selective biosensors for acetylcholine and acetylcholinesterase detection in human serum

The sensors’ analytical performance, including Nernstian response, detection limits, selectivity, stability, accuracy, repeatability, reproducibility, and application to acetylcholinesterase activity and acetylcholine quantification

Publication Details
Publication Date
2019-04-18
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Nashwa H. Ashmawy
Abdulrahman A. Almehizia
Teraze A. Youssef
Abd El‐Galil E. Amr
Mohamed A. Al‐Omar
Ayman H. Kamel
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%