Remote quantification of methane leaks in the laboratory and in biogas plants

Дистанционная количественная оценка утечек метана в лаборатории и на биогазовых установках
Andreas Kroll, Sören Dierks
2021-09-21

biogas plantsinfrared optical sensorsmethane leak quantificationremote measurement systemsensor data fusion
Gas leaks can occur not only in industrial environments such as refineries but also in biogas plants. The main compound of the emitted biogas is methane, which is a greenhouse gas with a higher global warming potential than carbon dioxide (CO 2). Considering that the climate change and the reduction of greenhouse gases are becoming more and more important, it is crucial to be able to not only localize but also to quantify methane leakages. Based on the quantification of methane leakages, not only the effect of the effluent gases to the atmosphere but also the economic loss can be estimated. Another aspect is safety: biogas consists of different gases, mainly methane which can create an explosive mixture with air, but also hydrogen sulphide, which is toxic. This motivates remotely measuring the gas emissions. In this paper a remote measurement system and model is presented to estimate the methane volume flow due to a leak based on infrared optical sensors and sensor data fusion. The sensors are calibrated and the system is tested in the laboratory as well as in biogas plants. The laboratory results show that the measurement model allows an estimation of the methane volume flow if the assumptions of the measurement model are met. The highest relative deviations occur for small reference methane volume flows while the absolute deviations are similar. In contrast to the laboratory measurements the results of the measurements in biogas plants show partially high deviations from the reference. These deviations can have multiple reasons which cannot be determined for each single case because many of them occur at the same time. Future work includes improvements in order to reduce the deviations of the methane volume flow estimation. This could be done not only by improving the processing steps of the velocity estimation but also by using more accurate sensors.
1
A remote measurement system combines infrared optical sensors and sensor-data fusion to estimate methane volume flow from leaks.
2
Laboratory testing shows that the measurement model estimates methane flow when its underlying assumptions are satisfied.
3
Reducing estimation errors will require improved velocity-processing methods and potentially more accurate sensors.
4
Relative errors are largest for small reference methane flows, while absolute deviations remain approximately similar across tested flows.
5
Tests at biogas plants produced partly large deviations from reference values, with multiple simultaneous causes preventing case-specific attribution.

Methane leaks and emissions from laboratory setups and biogas plants

Remote quantification of methane leak volume flow and the accuracy and deviations of its estimation

Publication Details
Publication Date
2021-09-21
Journal
Publisher
ISSN
Cited by
1
Access Type
Author Information
Authors
Andreas Kroll
Sören Dierks
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%