International Journal of Sports Medicine
International Journal of Sports Medicine
2026-11-04
SCID: 54.1/6r4rs4py
Discuss with AI
Bland-Altman agreementStO2 breakpointVO2max running testnear-infrared spectroscopyventilatory threshold 2
Figures from the paper
Abstract (AI)
The aim was to examine the association between this breakpoint (NIRS) and VT2 in welltrained runners.Gas exchange and NIRS data were collected during an incremental VO2max running test for 10 well-trained runners.The breakpoint calculated in oxygen saturation (StO2) and the VT2 were determined and compared in terms relative to %VO2max, absolute speed, VO2 and maximum heart rate (HRmax).There were no significant differences (p>0.05) between the breakpoint in StO2 and VT2 relative to %VO2max (87.00±6.14 and 88.28±3.98 %), absolute speed (15.70±1.42 and 16.10±1.66km•h -1 ), VO2 (53.71±15.17and 54.66±15.57ml•kg -1 •min -1 ) and %HRmax (90.90± 4.17 and 91.84 ± 3.70 %).There were large and significant correlations between instruments relative to %VO2max (r=0.68,p<0.05), absolute speed (r=0.86,p<0.001),VO2 (r=0.86,p<0.001) and %HRmax (r = 0.69; p<0.05).A Bland and Altman analysis of agreement between instruments resulted in a mean difference of -1.27±4.49%,-0.40±0.84km•h -1 , -0.90±3.07ml•kg -1 •min -1 , and -0.94±3.14 for %VO2max, absolute speed, VO2 and %HRmax, respectively.We conclude that a portable NIRS determination of the StO2 breakpoint is comparable with VT2 using gas exchange and therefore appropriate for use in determining exercise training above VT2 intensity.This is the first study to analyze the validity with the running mode using a NIRS portable device.
Key Findings
1
Bland–Altman analyses show small mean differences between instruments: −1.27±4.49% (%VO2max), −0.40±0.84 km·h⁻¹ (speed), −0.90±3.07 ml·kg⁻¹·min⁻¹ (VO2), and −0.94±3.14 (%HRmax).
2
Conclusion: Portable NIRS measurement of StO2 breakpoint is comparable to gas-exchange VT2 and appropriate for determining exercise training intensity above VT2 in well-trained runners; first validation using a running-mode portable NIRS device.
3
Large and significant correlations observed between NIRS StO2 breakpoint and VT2 for absolute speed (r=0.86, p<0.001), VO2 (r=0.86, p<0.001), %VO2max (r=0.68, p<0.05), and %HRmax (r=0.69, p<0.05).
4
No significant differences between StO2 breakpoint and VT2 for absolute speed (15.70±1.42 vs 16.10±1.66 km·h⁻¹), VO2 (53.71±15.17 vs 54.66±15.57 ml·kg⁻¹·min⁻¹), and %HRmax (90.90±4.17 vs 91.84±3.70%).
5
Portable NIRS-determined StO2 breakpoint shows no significant differences from VT2 for %VO2max (87.00±6.14 vs 88.28±3.98%).
Research Object
Portable NIRS device measurement of muscle oxygen saturation (StO2) breakpoint during incremental VO2max running tests in well-trained runners
Research Subject
Agreement and validity of the StO2 breakpoint measured by portable NIRS compared with second ventilatory threshold (VT2) determined by gas exchange, assessed via %VO2max, absolute running speed, VO2, and %HRmax
Publication Details
Publication Date
2026-11-04
Journal
Publisher
ISSN
Cited by
966
Access Type
Author Information
Download PDF