Chromium removal by a bipolar electro-chemical precipitation process
Удаление хрома методом биполярного электрохимического осаждения
1996-11-01
SCID: 54.1/6rq4xwdf
Discuss with AI
X-ray diffractionbipolar electrochemical precipitationchromium removalelectroplating wastewatermaghemite and chromite sludge
Figures from the paper
Abstract (AI)
This research was conducted in laboratory to investigate an alternative for Cr removal from an electroplating wastewater using the electro-chemical precipitation (ECP) process. The ECP unit, operated in the bipolar mode, had six steel plates including the anode and cathode and was supplied with DC power. The electroplating wastewater used in the experiments contained Cr concentrations in the range of 570-2100 mg/l. The Cr removal efficiencies in the bipolar ECP units were higher than 99% and the Cr concentrations in the treated effluent were less than 0.5 mg/l. The acceptable conditions of the bipolar ECP unit treating the electroplating wastewater were found to be: I - 1.0 amp (or i - 6.70 amp/m2) and initial pH (pHi) of 4.5. At these acceptable conditions, the electric power and steel electrode plate consumptions were 20.0 kWh/m3 and 1.1-2.8 kg-Fe/kg Cr removed, respectively. X-ray fluorescence and X-ray diffractometric analysis performed on the precipitated sludge revealed the main compounds to be maghemite (Fe2O3) and chromite (FeCr2O4). The percent Fe2O3 and FeCr2O4 contents of the dried ECP sludge were 68% and 25%, respectively. From the mass balance analysis, the percent of Cr removal by precipitation in the ECP unit and adsorption on the ECP sludge were 85.1 and 14.8%, respectively.
Key Findings
1
A bipolar electro-chemical precipitation process achieved over 99% chromium removal from electroplating wastewater containing 570–2100 mg/L Cr.
2
Acceptable operating conditions were 1.0 A (6.70 A/m²) and an initial pH of 4.5.
3
At these conditions, electricity consumption was 20.0 kWh/m³ and steel consumption was 1.1–2.8 kg Fe per kg Cr removed.
4
The sludge mainly contained maghemite (68%) and chromite (25%); chromium removal occurred through precipitation (85.1%) and adsorption onto sludge (14.8%).
5
Treated effluent chromium concentrations were reduced to below 0.5 mg/L using a six-steel-plate bipolar ECP unit.
Research Object
Chromium-containing electroplating wastewater treated in a bipolar electro-chemical precipitation unit
Research Subject
Chromium removal efficiency, operating conditions, energy and electrode consumption, precipitated-sludge composition, and removal mechanisms by precipitation and adsorption
Publication Details
Publication Date
1996-11-01
Journal
Publisher
ISSN
Access Type
Author Information
Download PDF
Subscribe to digest