Accuracy of half-guided implant placement with machine-driven or manual insertion: a prospective, randomized clinical study
Точность установки имплантатов при машинном или ручном введении в рамках полунавигируемого протокола: проспективное рандомизированное клиническое исследование
2021-08-16
SCID: 54.1/7aqp2s84
Discuss with AI
cone beam computed tomographyhalf-guided implant placementimplant placement accuracysurgical motortorque wrench
Figures from the paper
Abstract (AI)
OBJECTIVES: To compare the accuracy of implant placement performed with either a surgical motor or a torque wrench as part of a half-guided surgical protocol. MATERIALS AND METHODS: Implant insertion with half-guided surgical protocol was utilized by surgical motor (machine-driven group) or torque wrench (manual group) in the posterior maxilla. After the healing period, accuracy comparison between planned and actual implant positions was performed based on preoperative cone beam computed tomography and postoperative digital intraoral scans. Coronal, apical, and angular deviations, insertion time, and insertion torque were evaluated. RESULTS: Forty patients were treated with 1 implant each; 20 implants were inserted with a surgical motor and 20 implants with a torque wrench. Global coronal and apical deviations were 1.20 ± 0.46 mm and 1.45 ± 0.79 mm in the machine-driven group, and 1.13 ± 0.38 mm and 1.18 ± 0.28 mm in the manual group (respectively). The mean angular deviation was 4.82 ± 2.07° in the machine-driven group and 4.11 ± 1.63° in the manual group. Mean insertion torque was 21.75 ± 9.75 Ncm in the machine-driven group, compared to 18.75 ± 7.05 Ncm in the manual group. Implant placement duration was 9.25 ± 1.86 s in the machine-driven group at a speed of 50 rpm, and 36.40 ± 8.15 s in the manual group. CONCLUSION: No significant difference was found between the two groups in terms of accuracy and mean insertion torque, while machine-driven implant placement was significantly less time-consuming. CLINICAL RELEVANCE: Optimal implant placement accuracy utilized by half-guided surgical protocol can be achieved with both machine-driven and torque wrench insertion. TRIAL REGISTRATION: ID: NCT04854239.
Key Findings
1
A prospective randomized clinical study compared half-guided implant placement using a surgical motor versus a torque wrench in the posterior maxilla.
2
Both surgical motor and torque-wrench insertion achieved accurate implant placement within the half-guided surgical protocol.
3
Machine-driven insertion was significantly faster, requiring 9.25 ± 1.86 seconds compared with 36.40 ± 8.15 seconds for manual insertion.
4
No significant differences were found between machine-driven and manual insertion in coronal, apical, or angular accuracy, or in mean insertion torque.
5
The study included 40 patients, with 20 implants placed using each insertion method.
Research Object
Dental implants placed in the posterior maxilla using a half-guided surgical protocol with either machine-driven or manual insertion
Research Subject
Accuracy, insertion torque, and placement time of machine-driven versus manual implant insertion
Publication Details
Publication Date
2021-08-16
Journal
Publisher
ISSN
Cited by
17
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest