Reliability and Repeatability of the Motor and Sensory Examination of the International Standards for Neurological Classification of Spinal Cord Injury
Надёжность и воспроизводимость двигательного и сенсорного обследования в соответствии с Международными стандартами неврологической классификации повреждения спинного мозга
2008-01-01
SCID: 54.1/7b7jqsqt
Discuss with AI
interrater reliabilitymotor examinationneurological classificationsensory examinationspinal cord injury
Figures from the paper
Abstract (AI)
OBJECTIVE: To determine the reliability and repeatability of the motor and sensory examination of the International Standards for Classification of Spinal Cord Injury (SCI) in trained examiners. PARTICIPANTS/METHODS: Sixteen examiners (8 physicians, 8 physical therapists) with clinical SCI experience and 16 patients participated in a reliability study in preparation for a clinical trial involving individuals with acute SCI. After a training session on the standards, each examiner evaluated 3 patients for motor, light touch (LT), and pin prick (PP). The following day, 15 examiners reevaluated one patient. Interrater reliability was determined using intraclass correlation coefficients (1-way, random effects model). Intrarater reliability was determined using a 2-way random effects model. Repeatability was determined using the method of Bland and Altman. RESULTS: Patients were classified as complete tetraplegia (n = 5), incomplete tetraplegia (n = 5), complete paraplegia (n = 5), and incomplete paraplegia (n = 1). Overall, inter-rater reliability was high: motor = 0.97, LT = 0.96, PP = 0.88. Repeatability values were small in patients with complete SCI (motor < 2 points, sensory < 7 points) but large for patients with incomplete SCI. Intra-rater reliability values were > or = 0.98 for patients with complete SCI. CONCLUSIONS: The summed scores for motor, LT, and PP in subjects with complete SCI have high inter-rater reliability and small repeatability values. These measures are appropriately reliable for use in clinical trials involving serial neurological examinations with multiple examiners. Further research in subjects with incomplete SCI is needed to determine whether repeatability is acceptably small.
Key Findings
1
In trained examiners, inter-rater reliability was high for summed motor (0.97), light-touch (0.96), and pin-prick (0.88) examination scores.
2
Intra-rater reliability was at least 0.98 for patients with complete spinal cord injury.
3
Repeatability was large in patients with incomplete SCI, requiring further research to establish whether these measures are acceptably reliable.
4
Repeatability was small in patients with complete spinal cord injury, with motor differences below 2 points and sensory differences below 7 points.
5
Summed motor, light-touch, and pin-prick scores are sufficiently reliable for serial neurological examinations by multiple examiners in clinical trials involving complete SCI.
Research Object
Motor and sensory neurological examinations of patients with spinal cord injury (SCI), including complete and incomplete tetraplegia and paraplegia
Research Subject
Interrater and intrarater reliability and repeatability of summed motor, light-touch, and pin-prick scores performed by trained examiners
Publication Details
Publication Date
2008-01-01
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest