The diagnostic utility of lung ultrasound in the assessment of interstitial lung disease associated with rheumatoid arthritis
Диагностическая ценность ультразвукового исследования лёгких при оценке интерстициального заболевания лёгких, ассоциированного с ревматоидным артритом
2025-07-30
SCID: 54.1/89mfgx6p
Discuss with AI
B-lines scorehigh-resolution computed tomographyinterstitial lung diseaselung ultrasoundrheumatoid arthritis
Figures from the paper
Abstract (AI)
BACKGROUND: To investigate the diagnostic accuracy of lung ultrasound (LUS) for interstitial lung disease (ILD) in patients with rheumatoid arthritis (RA). METHODS: This retrospective study included patients over 18 years with RA evaluated at the Department of Rheumatology and Immunology of Shantou Central Hospital. All patients underwent chest high-resolution computed tomography (HRCT) and LUS within one month. The LUS was performed in a total of 50 scanning sites (ScS), and the number of B-lines present in each ScS was counted and summed up as B-lines score. A positive judgement was given on LUS when the B-lines score exceeded 10. The presence and patterns of ILD were defined by HRCT findings. ROC curve analysis was used to calculate the accuracy of LUS to detect ILD. RESULTS: A total of 120 RA patients (86 women, with a median age of 56.0 [50.0-64.0] years) were enrolled. Based on the HRCT, 76 patients were found to have radiographic ILD, with 63 exhibiting nonspecific interstitial pneumonia (NSIP) and 13 showing usual interstitial pneumonia (UIP). Sonographic ILD was detected in 76 patients who underwent LUS examination. The concordance rate between two modalities was 83.33% (Kappa value = 0.64, 95% CI 0.50-0.78). The diagnostic sensitivity and specificity of LUS were 86.84% and 77.27%, respectively. The positive predictive value, negative predictive value, a positive likelihood ratio and a negative likelihood ratio were 86.84%, 77.27%, 3.82, and 0.17, respectively. The number of B-lines in RA with ILD and without ILD on HRCT showed a significant difference (34.0 [15.0-96.5] vs. 6.5 [2.5-10.0], P < 0.001). The presence of 12 B-lines on 50 ScS was the optimal cutoff value for detecting RA-ILD (AUC = 0.89, 95% CI 0.82-0.94, sensitivity of 85.53%, specificity of 81.82%, P < 0.001). CONCLUSIONS: Lung ultrasound is a valuable diagnostic tool for RA-ILD and can be used as a screening method to identify patients who require further evaluation with chest HRCT.
Key Findings
1
A threshold of 12 B-lines across 50 scanning sites provided optimal diagnostic performance, with AUC=0.89, 85.53% sensitivity, and 81.82% specificity.
2
Lung ultrasound may serve as a screening tool to identify RA patients requiring further evaluation with chest HRCT.
3
Lung ultrasound showed substantial agreement with HRCT for detecting rheumatoid arthritis-associated interstitial lung disease, with an 83.33% concordance rate and κ=0.64.
4
Patients with HRCT-confirmed ILD had significantly more B-lines than patients without ILD: median 34.0 versus 6.5, respectively (P<0.001).
5
Using a B-lines score above 10, LUS detected RA-associated ILD with 86.84% sensitivity and 77.27% specificity.
Research Object
Interstitial lung disease associated with rheumatoid arthritis (RA-ILD) in adult patients with rheumatoid arthritis
Research Subject
Diagnostic accuracy and screening utility of lung ultrasound based on B-line counts for detecting RA-ILD, including NSIP and UIP patterns
Publication Details
Publication Date
2025-07-30
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest