Early Detection of Alterations in the Resonance Frequency Assessment of Oral Implant Stability on Various Bone Types: A Clinical Study
Раннее выявление изменений при оценке стабильности зубных имплантатов методом резонансно-частотного анализа в костной ткани различных типов: клиническое исследование
2010-03-16
SCID: 54.1/94v3nmes
Discuss with AI
Hounsfield unitsbone qualityimplant stability quotientosseointegrationresonance frequency analysis
Figures from the paper
Abstract (AI)
This study was undertaken to evaluate the relation between bone quality and alterations of implant stability quotient values measured during the initial phase of healing. Nineteen patients treated with 106 implants were included in the current study. The mean bone density of the implant recipient area was measured using Simplant 11 software incorporated in the computerized tomography (CT) machine. Mean bone density measurements were recorded in Hounsfield units. The implant recipient sites were subdivided into 5 groups according to bone quality. The numbers of the structures on the recipient site belonging to D1 and D5 types showed no statistical significance and were excluded. Standard 2-stage surgical technique was utilized to prepare the surgical sites. The implant stability quotient (ISQ) value at implant placement was recorded and did not influence the treatment procedure. The ISQ was measured by an Osstell instrument. The ISQ was further registered on the 21st and 60th days. SPSS statistical software was used for the statistical analysis. In comparison with the time of insertion, the mean values of the ISQ were decreasing for the first 21 days. However, on subsequent days, the ISQ values of all bone types have increased and on the 60th day reached the values recorded at the time of insertion. Analysis of the relation between changes in stability and bone type does not reveal statistical significance. With knowledge of the current clinical study, it can be concluded that bone quality in the recipient bone site does not effect changes in implant stability at the early stages of the osseointegration process.
Key Findings
1
After day 21, ISQ values increased in all bone types and returned to insertion-level values by day 60.
2
Changes in implant stability were not significantly associated with recipient-site bone quality during early osseointegration.
3
ISQ values decreased during the first 21 days after implant placement across the assessed bone-quality groups.
4
The findings suggest that bone quality does not affect early changes in implant stability during the initial osseointegration period.
5
The study evaluated early implant stability changes using implant stability quotient measurements in 106 implants placed in 19 patients.
Research Object
Dental implants placed in recipient jawbone sites of varying bone quality during early healing
Research Subject
The relationship between bone quality and changes in implant stability quotient (ISQ) during the early stages of osseointegration
Publication Details
Publication Date
2010-03-16
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest