The reliability and validity study of the Kinesthetic and Visual Imagery Questionnaire in individuals with Multiple Sclerosis

Исследование надежности и валидности Опросника кинестетической и зрительной образности у лиц с рассеянным склерозом
Nasser Zangiabadi, Farzaneh Zolala, Yousef Moghadas Tabrizi, Shahrzad Mazhari
2013-12-01

Kinesthetic and Visual Imagery Questionnaireconcurrent validitymotor imagerymultiple sclerosistest-retest reliability
OBJECTIVE: Motor imagery (MI) has been recently considered as an adjunct to physical rehabilitation in patients with multiple sclerosis (MS). It is necessary to assess MI abilities and benefits in patients with MS by using a reliable tool. The Kinesthetic and Visual Imagery Questionnaire (KVIQ) was recently developed to assess MI ability in patients with stroke and other disabilities. Considering the different underlying pathologies, the present study aimed to examine the validity and reliability of the KVIQ in MS patients. METHOD: Fifteen MS patients were assessed using the KVIQ in 2 sessions (5-14 days apart) by the same examiner. In the second session, the participants also completed a revised MI questionnaire (MIQ-R) as the gold standard. Intra-class correlation coefficients (ICCs) were measured to determine test-retest reliability. Spearman's correlation analysis was performed to assess concurrent validity with the MIQ-R. Furthermore, the internal consistency (Cronbach's alpha) and factorial structure of the KVIQ were studied. RESULTS: The test-retest reliability for the KVIQ was good (ICCs: total KVIQ=0.89, visual KVIQ=0.85, and kinesthetic KVIQ=0.93), and the concurrent validity between the KVIQ and MIQ-R was good (r=0.79). The KVIQ had good internal consistency, with high Cronbach's alpha (alpha=0.84). Factorial analysis showed the bi-factorial structure of the KVIQ, which was explained by visual=57.6% and kinesthetic=32.4%. CONCLUSIONS: The results of the present study revealed that the KVIQ is a valid and reliable tool for assessing MI in MS patients.
1
Factorial analysis supported a two-factor KVIQ structure comprising visual imagery, explaining 57.6%, and kinesthetic imagery, explaining 32.4%.
2
KVIQ scores showed good concurrent validity against the revised Motor Imagery Questionnaire, with a Spearman correlation of r=0.79.
3
The Kinesthetic and Visual Imagery Questionnaire (KVIQ) demonstrated good test-retest reliability in multiple sclerosis patients, with total, visual, and kinesthetic ICCs of 0.89, 0.85, and 0.93.
4
The findings support the KVIQ as a valid and reliable instrument for assessing motor imagery ability in people with multiple sclerosis.
5
The questionnaire demonstrated good internal consistency, with a Cronbach’s alpha of 0.84.

individuals with multiple sclerosis

the validity, reliability, internal consistency, and factorial structure of the Kinesthetic and Visual Imagery Questionnaire for assessing motor imagery ability

Publication Details
Publication Date
2013-12-01
Journal
Publisher
ISSN
Cited by
30
Access Type
Author Information
Authors
Nasser Zangiabadi
Farzaneh Zolala
Yousef Moghadas Tabrizi
Shahrzad Mazhari
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%