Due to the increasing number of battery electric vehicles (BEV) on the roads and the number of BEV accidents with the occurrence of a fire, full-scale fire tests of BEVs were carried out. For initiation, the BEVs were mechanically damaged, forming a gap with a size of 15 cm × 15 cm. The external heat source was a 300 kW propane burner with a maximum power of 54.0 kW and a length of 54 cm. The flame of the propane–butane fuel mixed in air at a temperature of 1970 °C was inserted directly into the battery pack. The increase in the temperature was monitored as a function of time through thermocouples at selected locations of the BEV until the point of initiation. Thermocouples were placed 10, 30, and 50 cm from the place of BEV surface. Accordingly, to obtain the temperature–time curves from the experiment measurement, critical temperatures were subsequently evaluated. The fire tests on BEVs can be described according to the individual phases of the fire. The external heat source started the initiation process at the 25 min time mark. Consequently, the phase of a developed fire with a dynamic course started. A sharp rise in temperature occurred. Within two minutes, the temperature rose to 1056.9 °C. After the initiation source was removed, there was decline in temperature and re-ignition to the stage of a fully developed fire. Thermocouples recorded temperatures in the range of 900 °C. The resulting dynamic process of a BEV fire with a sharp increase in temperature is a problem for the implementation of firefighting works and the liquidation of traffic accidents. Furthermore, foam extinguishing was part of the experiments. In both cases after the foam application, the temperature on the thermocouple T1 (distance was 10 cm from the surface of the BEV) dropped from 486.1 °C to 76 °C after 10 s of application.
1
Foam application reduced the temperature at the thermocouple 10 cm from the vehicle surface from 486.1 °C to 76 °C within 10 seconds.
2
Full-scale BEV fire tests used a 300 kW propane burner and direct flame exposure through a mechanically created 15 cm × 15 cm battery-pack opening.
3
Removing the ignition source caused an initial temperature decline followed by re-ignition and progression to a fully developed fire.
4
Temperature increased sharply to 1056.9 °C within two minutes after initiation, while thermocouples later recorded temperatures around 900 °C.
5
The external heat source initiated the BEV fire after approximately 25 minutes, followed by a rapidly developing fire phase.

battery electric vehicles (BEVs) subjected to full-scale fire tests

fire initiation, temperature–time evolution, fire phases, re-ignition, and foam-extinguishing response

Publication Details
Publication Date
2024-05-09
Journal
Applied Sciences
Publisher
Multidisciplinary Digital Publishing Institute
ISSN
2076-3417
Cited by
7
Access Type
Author Information
Authors
Jozef Svetlík
Zoltan Tancos
Petr Tancos
Iveta Marková
Kristián Slašťan
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%