A Proposal for a New Lung Ultrasound Score in Rheumatoid Arthritis: The Reliability of Lung Ultrasound for Rheumatoid Arthritis-Associated Interstitial Lung Disease Diagnosis
Предложение новой шкалы ультразвукового исследования легких при ревматоидном артрите: надежность ультразвукового исследования легких для диагностики интерстициального заболевания легких, ассоциированного с ревматоидным артритом
2025-05-25
SCID: 54.1/b2uuqpyb
Discuss with AI
B-line scoreinter-explorer reliabilitylung ultrasoundpleural line scorerheumatoid arthritis-associated interstitial lung disease
Figures from the paper
Abstract (AI)
Background/Objectives: The objective of this study is to investigate the intra- and inter-explorer reliability of different lung ultrasound (LUS) scores in patients with suspected rheumatoid arthritis with associated interstitial lung disease (RA-ILD). Methods: Fourteen consecutive patients with suspected RA-ILD based on the presence of respiratory symptoms, lung function tests (LFTs) or imaging alterations were recruited. The screening protocol consisted of an LFT, a chest X-ray, and HRCT. LUS examinations of different B-line and pleural line scores including 14 intercostal spaces were performed by three experienced sonographers, guaranteeing blinding. Intra- and inter-explorer reliability were calculated for all LUS scores and at the intercostal space level by weighted Cohen’s kappa and Fleiss’ kappa, respectively, relying on absolute differences using Stata/IC 14.2 software® (StataCorp, College Station, TX, USA). Results: Both global (ĸ = 0.73–0.82) and binary (ĸ = 0.80–0.90) scores of B lines showed substantial to excellent intra-explorer reliability, with slightly better results for the binary score. The inter-explorer reliability was equally excellent for the global score (ĸ = 0.93) and the binary score (ĸ = 0.90) of B lines. The intra-explorer reliability of the semiquantitative pleural score was excellent for all the sonographers (ĸ = 0.88–0.91), and the binary pleural score had slightly lower intra-explorer reliability (ĸ = 0.77–0.84). Regarding inter-explorer reliability, both semiquantitative and binary pleural scores were equally excellent (ĸ = 0.84). Good to excellent inter-explorer reliability was found in all the scanned areas. Conclusions: Substantial to excellent intra- and inter-explorer reliability of different feasible B-line and pleural LUS scores were found, adding evidence in favor of the potential implementation of LUS for RA-ILD diagnosis in clinical practice.
Key Findings
1
B-line scores demonstrated intra-explorer reliability of κ = 0.73–0.82 globally and κ = 0.80–0.90 binarily, with slightly better binary-score performance.
2
Both pleural scoring approaches achieved excellent inter-explorer reliability (κ = 0.84), supporting potential clinical implementation of LUS for RA-ILD diagnosis.
3
Different feasible lung ultrasound B-line and pleural-line scoring systems showed substantial-to-excellent intra- and inter-explorer reliability in suspected RA-ILD.
4
Inter-explorer reliability was excellent for both global and binary B-line scores, with κ = 0.93 and κ = 0.90, respectively.
5
Semiquantitative pleural scores showed excellent intra-explorer reliability (κ = 0.88–0.91), while binary pleural scores were slightly lower (κ = 0.77–0.84).
Research Object
Lung ultrasound assessment in patients with suspected rheumatoid arthritis-associated interstitial lung disease (RA-ILD)
Research Subject
Intra- and inter-explorer reliability of B-line and pleural-line lung ultrasound scores for RA-ILD diagnosis
Publication Details
Publication Date
2025-05-25
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest