Risk Assessment of Dental Unit Waterline Contamination
Оценка риска загрязнения водопроводных линий стоматологических установок
2003-01-01
SCID: 54.1/crfjcdpq
Discuss with AI
biofilm contaminationdental unit waterlinesinfection-control measuresrespiratory pathogensrisk assessment
Figures from the paper
Abstract (AI)
Biofilms form rapidly on dental unit waterlines. The majority of the organisms in the biofilm are harmless environmental species, but some dental units may harbour opportunistic respiratory pathogens. This paper describes a risk assessment approach to analysing the hazard from biofilm organisms contaminating dental unit waterlines on the respiratory health of both the dental team and patients. The health risk from the respiratory pathogens Legionella spp, Mycobacterium spp and Pseudomonads was found to be low. Nevertheless, in order to satisfy water regulations and comply with health and safety legislation dentists should institute infection-control measures to maintain the dental unit water at the standard of less than 200 colony-forming units per ml of aerobic bacteria.
Key Findings
1
A risk-assessment approach was used to evaluate respiratory hazards from dental-unit-waterline biofilms for dental personnel and patients.
2
Dental unit waterlines rapidly develop biofilms, predominantly containing harmless environmental organisms but sometimes harboring opportunistic respiratory pathogens.
3
Despite the low risk, infection-control measures are recommended to meet regulations and maintain aerobic bacterial counts below 200 colony-forming units per milliliter.
4
The assessed respiratory health risk from Legionella spp., Mycobacterium spp., and Pseudomonads was found to be low.
Research Object
Biofilm contamination of dental unit waterlines
Research Subject
Respiratory health risk from opportunistic pathogens, including Legionella spp., Mycobacterium spp., and Pseudomonads, and the need for infection-control measures to maintain bacterial levels below 200 colony-forming units per ml
Publication Details
Publication Date
2003-01-01
Journal
Publisher
ISSN
Access Type
Author Information
Download PDF
Subscribe to digest