Validation of Short Tandem Repeats (STRs) for Forensic Usage: Performance Testing of Fluorescent Multiplex STR Systems and Analysis of Authentic and Simulated Forensic Samples

Валидация коротких тандемных повторов (STR) для судебно-экспертного применения: испытание характеристик флуоресцентных мультиплексных систем STR и анализ аутентичных и смоделированных судебно-экспертных образцов
TR Moretti, Annette Baumstark, DA Defenbaugh, KM Keys, JB Smerick, B Budowle
2001-05-01

CODIS lociforensic DNA analysismultiplex PCRshort tandem repeatsstutter products
The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR Profiler Plus and AmpFlSTR COfiler (Applied Biosystems, Foster City, CA), GenePrint PowerPlex (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO II Fluorescent Imaging Device, and the Fluorlmager were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.
1
Although fluorophore-associated interlocus balance was sometimes imperfect, results remained reliable; criteria were proposed for identifying single-source versus mixed DNA samples using peak counts, stutter heights, and peak-height patterns.
2
Authentic, environmentally compromised, and body-fluid samples deposited on diverse substrates produced valid and robust STR results.
3
Performance testing evaluated multiplex PCR ranges, detection sensitivity, non-allelic products, heterozygous peak balance, locus-specific stutter, stochastic thresholds, and mixed-DNA detection.
4
The 13 core CODIS STR loci were successfully amplified and typed using commercially available fluorescent multiplex systems across multiple detection platforms.
5
The evaluated systems showed no evidence of false-positive or false-negative results and no substantial within-locus preferential amplification.

13 core CODIS short tandem repeat (STR) loci and their fluorescent multiplex PCR systems applied to human forensic DNA samples

Forensic performance, analytical sensitivity, amplification artifacts, peak balance, stochastic thresholds, and mixture interpretation of multiplex STR typing systems

Publication Details
Publication Date
2001-05-01
Journal
Publisher
ISSN
Access Type
Author Information
Authors
TR Moretti
Annette Baumstark
DA Defenbaugh
KM Keys
JB Smerick
B Budowle
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%