Recording the tibial H reflex from the calf is routine in clinical electromyography. Two widely used methods are Hugon's and Braddom and Johnson's. Both methods produce an H wave with an initial positive deflection. Another method, the "half and half" method, generates an H wave with an initial negative deflection. To compare these methods, H-reflex responses were recorded in the right calf of 20 normal adults with each method using identical amplifier and stimulator settings. Stimulus current was increased by increments of 0.5-1.0 mA until the H reflex and motor (M) wave responses reached maximum amplitudes (Hmax, Mmax). H wave to M wave (H/M) amplitude ratios were calculated. The half-and-half method produced greatest Hmax, Mmax, and H/M ratio. Wave form configuration for the half-and-half method was biphasic with an initial negative deflection; it was triphasic with an initial positive deflection with the other methods. The shapes of M and H waves were similar in two methods but dissimilar in one. Because of the greater amplitude and the initial negative deflection, the H wave may be easier to detect with the half-and-half method and may present a latency that is more easily determined. For these reasons, the half-and-half method is recommended for measuring amplitude and latency in clinical settings.
Key Findings
1
Because of greater amplitude and initial negative deflection, the half-and-half method likely allows easier H-wave detection and more easily determined latency, and is recommended for clinical amplitude and latency measurements.
2
M and H wave shapes were similar for two methods but dissimilar for one (implying waveform similarity varied by method).
3
The half-and-half method produced the largest Hmax, Mmax, and H/M amplitude ratio compared with the other two methods.
4
Three tibial H-reflex recording methods (Hugon, Braddom and Johnson, half-and-half) were compared on 20 normal adults using identical settings.
5
Waveform morphology differed: half-and-half method yielded a biphasic H wave with initial negative deflection; Hugon and Braddom and Johnson methods yielded triphasic H waves with initial positive deflection.
Research Object
Methods for recording the tibial H reflex from the calf (Hugon's method, Braddom and Johnson's method, and the half-and-half method)
Research Subject
Comparative performance of these recording methods in terms of Hmax, Mmax, H/M amplitude ratio, H- and M-wave waveform configuration (initial deflection polarity and phasicity), detectability, and latency determination