Comparative analysis of dimensional changes in autoclavable polyvinyl siloxane (PVS) impressions under various Sterilization/Disinfection Protocols: A randomized controlled trial

Сравнительный анализ размерных изменений автоклавируемых слепков из поливинилсилоксана (PVS) при различных протоколах стерилизации/дезинфекции: рандомизированное контролируемое исследование
Noha Taymour, Sanaa H. Abdel Kader, Mohammed M. Gad, Moustafa N. Aboushelib
2024-02-04

AFFINISautoclavable polyvinyl siloxane (PVS)chemical disinfection (5.25% NaOCl, 2% glutaraldehyde)dimensional stabilityinter-abutment and intra-abutment measurementsone-way ANOVA (α = 0.05)randomized controlled trialsteam autoclaving (134 °C, 18 min)universal measuring microscope (0.001 mm precision)
Background: Impressions that maintain their dimensional stability after autoclaving effectively control cross-infection and contamination resulting from a patient's oral secretions. Purpose: The study aimed to assess the dimensional stability of autoclavable polyvinyl siloxanes after disinfection and sterilization. Methods: , BK Giulini Chemie, Ludwigshafen/Rh., Germany). The dimensional accuracy of the obtained casts was assessed by measuring the inter-abutment measurements (between the abutments) and the intra-abutment measurements (diameter and height of the abutments). These measurements were performed using a universal measuring microscope (Olympus stereomicroscope B061 Imaging Corp. Tokyo, Japan) with a precision of 0.001 mm. The dimensions of the stone casts from the study groups were then compared to those of the control group. Data analysis was performed using a one-way ANOVA with a significance level of α = 0.05. Results: AFFINIS impressions subjected to chemical disinfection in 5.25 % NaOCl and 2 % glutaraldehyde with different immersion times showed slight expansion in the intra- and inter-abutment measurements. The impressions autoclaved at 134 °C for 18 min showed slight shrinkage in the intra- and inter-abutment measurements. The dimensional change was statistically non-significant, and the percent of dimensional changes within the experimental groups was within the clinically accepted limit (α < 0.5). Conclusion: AFFINIS polyvinyl siloxanes retain dimensional stability suitable for clinical use when subjected to chemical disinfection and steam autoclaving.
1
AFFINIS autoclavable polyvinyl siloxane (PVS) impressions chemically disinfected in 5.25% NaOCl and 2% glutaraldehyde showed slight expansion in intra- and inter-abutment measurements.
2
AFFINIS impressions autoclaved at 134 °C for 18 minutes exhibited slight shrinkage in intra- and inter-abutment measurements.
3
All observed dimensional changes across chemical disinfection and steam autoclaving were statistically non-significant (one-way ANOVA, α = 0.05).
4
Dimensional accuracy was assessed using inter-abutment and intra-abutment (diameter and height) measurements with a microscope precision of 0.001 mm, comparing stone casts to a control group.
5
Percent dimensional changes for experimental groups remained within the clinically accepted limit (α < 0.5), indicating suitability for clinical use after disinfection or autoclaving.

Autoclavable polyvinyl siloxane (AFFINIS) dental impressions

Dimensional stability/changes (intra- and inter-abutment measurements) after various sterilization/disinfection protocols (chemical immersion in 5.25% NaOCl and 2% glutaraldehyde, and steam autoclaving at 134 °C for 18 min)

Publication Details
Publication Date
2024-02-04
Journal
Publisher
ISSN
Cited by
4
Access Type
Author Information
Authors
Noha Taymour
Sanaa H. Abdel Kader
Mohammed M. Gad
Moustafa N. Aboushelib
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%