Rapid and Accurate Determination of Nanopore Ionic Current Using a Steric Exclusion Model

Быстрое и точное определение ионного тока через нанопоры с использованием модели стерического исключения
Aleksei Aksimentiev, Kumar Sarthak, James N. Wilson, Wei Si, Luyu Gao
2019-03-01

all-atom molecular dynamicsnanopore conductance mapnanopore ionic currentnanopore sensingsteric exclusion model
Nanopore sensing has emerged as a versatile approach to detection and identification of biomolecules. Presently, researchers rely on experience and intuition for choosing or modifying the nanopores to detect a target analyte. The field would greatly benefit from a computational method that could relate the atomic-scale geometry of the nanopores and analytes to the blockade nanopore currents they produce. Existing computational methods are either computationally too expensive to be used routinely in experimental laboratories or not sensitive enough to account for the atomic structure of the pore and the analytes. Here, we demonstrate a robust and inexpensive computational approach-the steric exclusion model (SEM) of nanopore conductance-that is orders of magnitude more efficient than all-atom MD and yet is sensitive enough to account for the atomic structure of the nanopore and the analyte. The method combines the computational efficiency of a finite element solver with the atomic precision of a nanopore conductance map to yield unprecedented speed and accuracy of ionic current prediction. We validate our SEM approach through comparison with the current blockades computed using the all-atom molecular dynamics method for a range of proteins confined to a solid-state nanopore, biological channels embedded in a lipid bilayer membranes, and blockade currents produced by DNA homopolymers in MspA. We illustrate potential applications of SEM by computing blockade currents produced by nucleosome proteins in a solid-state nanopore, individual amino acids in MspA, and by testing the effect of point mutations on amino acid distinguishability. We expect our SEM approach to become an integral part of future development of the nanopore sensing field.
1
Applications demonstrate SEM’s utility for predicting nucleosome blockade currents, distinguishing individual amino acids in MspA, and evaluating point-mutation effects.
2
SEM is orders of magnitude more computationally efficient than all-atom molecular dynamics, enabling routine use in experimental laboratories.
3
SEM predictions were validated against all-atom molecular dynamics for proteins, biological channels in lipid membranes, and DNA homopolymers in MspA.
4
The method combines a finite-element solver with an atomic-resolution nanopore conductance map to achieve fast, accurate current predictions.
5
The steric exclusion model (SEM) predicts nanopore ionic currents rapidly and inexpensively while retaining sensitivity to atomic pore and analyte structures.

Ionic currents and blockade currents generated by biomolecules confined in solid-state nanopores or biological nanopore channels

Rapid and accurate prediction of nanopore conductance and biomolecular current blockades from the atomic-scale geometry of nanopores and analytes using the steric exclusion model

Publication Details
Publication Date
2019-03-01
Journal
Publisher
ISSN
Cited by
74
Access Type
Author Information
Authors
Aleksei Aksimentiev
Kumar Sarthak
James N. Wilson
Wei Si
Luyu Gao
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%