Fault detection of photovoltaic array based on Grubbs criterion and local outlier factor
Обнаружение неисправностей фотоэлектрических массивов на основе критерия Граббса и локального коэффициента выброса
2019-12-09
SCID: 54.1/jd9pqu8f
Discuss with AI
Grubbs criterionLocal outlier factorPV module faultsPartial shadingPhotovoltaic array fault detection
Figures from the paper
Abstract (AI)
Aiming at improving the effectiveness and real‐time performance of the fault detection of the photovoltaic (PV) array under different outdoor conditions, a novel method based on Grubbs criterion and local outlier factor (G‐LOF) method is proposed in this study. The simulation model of the PV array is built to obtain the reference current of each PV string. The local outlier factor (LOF) is a ratio of the average local reachability density of sample neighbourhoods relative to its local reachability density. In this study, the LOF is used to quantify the abnormality by comparing the measured current and the simulated reference current. To reduce the false alarm probability of LOF, the Grubbs criterion is utilised as the test criterion to detect the abnormality of PV strings and it is merged with the LOF to derivate the G‐LOF. The experiments of partial shading, open‐circuit fault and short‐circuit fault of PV modules are implemented in sunny and cloudy days. Experimental results verify that the proposed G‐LOF method can sensitively detect above abnormalities, especially can detect the slight performance reduction caused by the partial shading or faults.
Key Findings
1
Experiments under sunny and cloudy conditions evaluated partial shading, open-circuit, and short-circuit module faults.
2
G-LOF sensitively detected all tested abnormalities, including slight performance reductions caused by partial shading or faults, while targeting improved real-time effectiveness.
3
The Grubbs criterion is incorporated to reduce false alarms associated with standalone local outlier factor detection.
4
The method compares measured PV-string currents with simulated reference currents to quantify abnormal operating behavior.
5
The study proposes G-LOF, combining the Grubbs criterion with local outlier factor analysis for photovoltaic-array fault detection.
Research Object
photovoltaic (PV) array and its PV strings/modules under outdoor operating conditions
Research Subject
detection of abnormal performance and faults, including partial shading, open-circuit faults, and short-circuit faults, using measured-versus-reference string currents
Publication Details
Publication Date
2019-12-09
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest