Kerr non-linearity enhances the response of a graphene Josephson bolometer

Нелинейность Керра повышает отклик графенового джозефсоновского болометра
Joydip Sarkar, Krishnendu Maji, Abhishek Sunamudi, Heena Agarwal, Priyanka Samanta, Anirban Bhattacharjee, Rishiraj Rajkhowa, Meghan P. Patankar, Kenji Watanabe, Takashi Taniguchi, Mandar M. Deshmukh
2025-07-31

Josephson parametric amplifierKerr nonlinearitygraphene Josephson bolometernoise-equivalent powersingle-photon detectors
Bolometers are radiation sensors that are central to wide areas such as dark matter search, radio astronomy, material science, and qubit readouts, among others. There have been different kinds of bolometer realizations in the recent past. The challenge is to have a single device that combines high sensitivity, broad bandwidth, and a fast readout scheme. Here we demonstrate the usage of Josephson parametric amplifiers (JPA) as highly sensitive bolometers. Our key finding is that the Kerr non-linearity of the JPA boosts the device’s sensitivity. When the bolometer is biased in the non-linear regime, it enhances the up-converted signals (~100 times), resulting in an order of magnitude improvement in sensitivity compared to the linear regime. In the non-linear biasing, we achieve a NEP ~ 500 aW/ $$\sqrt{{{{\rm{Hz}}}}}$$ . Our device offers a fast detection scheme with a thermal time constant of 4.26 μs and an intrinsic JPA time constant of 70 ns. Our work integrates a JPA into a bolometer, enabling a fast and sensitive operation compared to previously studied graphene-based bolometers. Our study demonstrates a way forward to improve the quantum sensors based on 2D materials by leveraging the inherent non-linear response. Graphene-based Josephson junction bolometers hold promise as sensitive single-photon detectors, but they are normally limited by slow readout schemes and narrow operational bandwidths. Here, the authors report the application of Josephson parametric amplifiers as fast, tunable bolometers with sensitivity enhanced by the intrinsic Kerr non-linearity.
1
Integrating a JPA provides a fast, tunable readout that addresses the slow readout and narrow bandwidth limitations of graphene-based bolometers.
2
Josephson parametric amplifiers can function as highly sensitive graphene Josephson bolometers for radiation detection.
3
Kerr-nonlinear biasing improves sensitivity by an order of magnitude, achieving a noise-equivalent power of approximately 500 aW/√Hz.
4
Operating the bolometer in the JPA’s nonlinear Kerr regime enhances up-converted signals by approximately 100 times compared with the linear regime.
5
The device combines fast thermal detection with a 4.26 μs thermal time constant and a 70 ns intrinsic JPA time constant.

graphene-based Josephson junction bolometers incorporating Josephson parametric amplifiers

the enhancement of bolometer sensitivity, signal up-conversion, bandwidth, and readout speed by the JPA’s Kerr non-linearity

Publication Details
Publication Date
2025-07-31
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Joydip Sarkar
Krishnendu Maji
Abhishek Sunamudi
Heena Agarwal
Priyanka Samanta
Anirban Bhattacharjee
Rishiraj Rajkhowa
Meghan P. Patankar
Kenji Watanabe
Takashi Taniguchi
Mandar M. Deshmukh
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%