Comparison of Effect Efficiency and Voltage Regulation Between Three-Phase Transformer Winding Connections
Сравнение эффективности и регулирования напряжения для схем обмоток трехфазных трансформаторов
2020-08-02
SCID: 54.1/kh7jdede
Discuss with AI
Dd0Dy5Yd11Yy0efficiencyresistive inductive capacitive loadsthree-phase transformer winding connectionsvoltage regulationzig-zag ZZ
Figures from the paper
Abstract (AI)
A transformer is an important device in electrical processes, as we know static electricity that involves magnetically coupled coils to increase or decrease the voltage. In three-phase transformer, there are various winding connections such as delta-delta (?, ?), wye-wye (Y, Y), wye-delta (Y, ?), delta-wye (?, Y), zig-zag (Z, Z), etc. And of the many often used connection are Yy0, Yd11, Dd0, and Dy5. From these various connections, each connection has different efficiency, losses, and voltage regulation. If they are connected with resistive, inductive, or capacitive loads. This paper method has discussed a transformer connection used are Yy0, Dd0, Yd11, and Dy5 in Laboratory Konversi Energi USU to see how the influence of load changes, on voltage regulation Where a state of balance load using are resistive, inductive, capacitive, and RLC combination. The result analysis of the experiment show, the best efficiency is at Dd0 connection, when loaded condition using capacitive is average 97.87%, and the best voltage regulation is obtained at Dy5, when loaded condition using resistive is average 28.35%
Key Findings
1
Dd0 connection achieved the highest efficiency under capacitive loading, with an average efficiency of 97.87%.
2
Different winding connections exhibit distinct efficiency, losses, and voltage regulation behaviors depending on load type (resistive, inductive, capacitive, RLC).
3
Dy5 connection produced the best (lowest) voltage regulation under resistive loading, with an average voltage regulation of 28.35%.
4
Experimental comparison evaluated Yy0, Dd0, Yd11, and Dy5 three-phase transformer winding connections under resistive, inductive, capacitive, and RLC balanced loads.
Research Object
Three-phase transformer with different winding connections (Yy0, Yd11, Dd0, Dy5) under various load types
Research Subject
Comparison of efficiency, losses, and voltage regulation for the specified three-phase winding connections under resistive, inductive, capacitive, and RLC balanced load conditions
Publication Details
Publication Date
2020-08-02
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest