Microbiological investigations of rainwater and graywater collected for toilet flushing
Микробиологические исследования дождевой и серой воды, собираемой для смыва унитаза
2002-09-01
SCID: 54.1/kkqvpnxj
Discuss with AI
AeromonasCampylobacter jejuniCryptosporidiumEnterococcusEscherichia coliLegionella non-pneumophilaMycobacterium aviumPseudomonas aeruginosagraywater reuseheterotrophic plate counts (R2A, PCA)household pathogen introductionmicrobial water qualityrainwater systemstoilet flushingtotal bacterial counts (AODC)
Figures from the paper
Abstract (AI)
Seven Danish rainwater systems were investigated with respect to the microbial water quality. The general microbiological quality (total numbers of bacteria (AODC)), and heterotrophic plate counts on R2A and Plate Count Agar in the toilets supplied with rainwater were approximately the same as in the reference toilets supplied with drinking water. However, in 12 of the 27 analysed samples one or more pathogens were observed (Aeromonas sp., Pseudomonas aeruginosa, Legionella non-pneumophila, Campylobacter jejuni, Mycobacterium avium, and Cryptosporidium sp.). These pathogens were not found in any of the reference toilets (32 toilets). This means that the use of rainwater introduced new, potentially pathogenic microorganisms into the households which would normally not occur in toilets supplied with water from waterworks. Furthermore, four graywater systems were investigated where water from the shower and hand wash basin was reused. The graywater systems gave more problems in terms of bad smell and substantially higher numbers of E. coli and Enterococcus in some toilet bowls supplied with graywater.
Key Findings
1
Graywater systems (shower and hand basin reuse) caused more odor problems and produced substantially higher E. coli and Enterococcus counts in some toilet bowls compared with rainwater or drinking water systems.
2
None of the listed pathogens were detected in any of the 32 reference toilets supplied with drinking water, indicating rainwater introduced potentially pathogenic microorganisms into households.
3
Pathogens (Aeromonas sp., Pseudomonas aeruginosa, Legionella non-pneumophila, Campylobacter jejuni, Mycobacterium avium, Cryptosporidium sp.) were detected in 12 of 27 rainwater samples.
4
Total bacterial counts (AODC) and heterotrophic plate counts (R2A and PCA) in toilets supplied with rainwater were approximately the same as in reference drinking-water toilets.
Research Object
Rainwater and graywater systems used for toilet flushing in households
Research Subject
Microbiological water quality and presence of pathogenic microorganisms (total bacterial counts, heterotrophic plate counts, occurrence of Aeromonas, Pseudomonas aeruginosa, Legionella non-pneumophila, Campylobacter jejuni, Mycobacterium avium, Cryptosporidium, E. coli, Enterococcus) and associated odors in toilets supplied with rainwater or reused graywater
Publication Details
Publication Date
2002-09-01
Journal
Publisher
ISSN
Access Type
Author Information
Download PDF
Subscribe to digest