Conductance-Based Determination of Solid-State Nanopore Size and Shape: An Exploration of Performance Limits
Определение размера и формы твердотельных нанопор на основе проводимости: исследование пределов применимости
2012-09-25
SCID: 54.1/m498fkq7
Discuss with AI
conductance-based geometry determinationconical-cylindrical modelelectrolyte-dependent conductancenanopore size and shapesolid-state nanopores
Figures from the paper
Abstract (AI)
Knowledge of nanopore size and shape is critical for many implementations of these single-molecule sensing elements. Geometry determination by fitting the electrolyte-concentration-dependence of the conductance of surface-charged, solid-state nanopores has been proposed to replace demanding electron microscope-based methods. The functional form of the conductance poses challenges for this method by restricting the number of free parameters used to characterize the nanopore. We calculated the electrolyte-dependent conductance of nanopores with an exponential-cylindrical radial profile using three free geometric parameters; this profile, itself, could not be uniquely geometry-optimized by the conductance. Several different structurally simplified models, however, generated quantitative agreement with the conductance, but with errors exceeding 40% for estimates of key geometrical parameters. A tractable conical-cylindrical model afforded a good characterization of the nanopore size and shape, with errors of less than 1% for the limiting radius. Understanding these performance limits provides a basis for using and extending analytical nanopore conductance models.
Key Findings
1
A tractable conical-cylindrical model accurately characterizes nanopore size and shape, estimating the limiting radius with less than 1% error.
2
An exponential-cylindrical radial profile with three geometric parameters cannot be uniquely optimized from conductance measurements alone.
3
Electrolyte-dependent conductance can characterize solid-state nanopore geometry, offering an alternative to electron microscopy.
4
Structurally simplified models can quantitatively fit conductance while producing errors exceeding 40% in key geometric parameter estimates.
5
These performance limits establish guidance for applying and extending analytical nanopore conductance models.
Research Object
Surface-charged solid-state nanopores with conical-cylindrical or exponential-cylindrical radial geometries
Research Subject
Accuracy and performance limits of determining nanopore size and shape from electrolyte-concentration-dependent conductance
Publication Details
Publication Date
2012-09-25
Journal
Publisher
ISSN
Cited by
54
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai7
Surface-Charge-Governed Ion Transport in Nanofluidic Channels2004
Salt Dependence of Ion Transport and DNA Translocation through Solid-State Nanopores2005
Counting and Sizing of Submicron Particles by the Resistive Pulse Technique1970
Modeling the conductance and DNA blockade of solid-state nanopores2011
Rapid Fabrication of Uniformly Sized Nanopores and Nanopore Arrays for Parallel DNA Analysis2006
Effects of Biological Reactions and Modifications on Conductance of Nanofluidic Channels2005
Reconstructing solid state nanopore shape from electrical measurements2010