Recovery of copper and plastics from discarded cable waste using vibratory separation: Experimental optimization, statistical modeling, and process evaluation

Извлечение меди и пластмасс из отходов отработанных кабелей с использованием вибрационной сепарации: экспериментальная оптимизация, статистическое моделирование и оценка процесса
Abdennour Bouziane, Farouk Benallel Boukhoulda, Amar Encadreur Tilmatine
2026-01-01

cable waste recyclingcopper recovery and puritycopper–plastic separationresponse surface regressionvibratory separation
The recycling of discarded electrical cables is important for recovering valuable copper and reducing the environmental burden of polymeric insulation waste. This study investigates a laboratory-scale vibratory separation system for recovering copper and plastic fractions from mechanically crushed cable waste. The objective was to evaluate the effects of motor speed and table inclination on separation efficiency and to develop statistical models for recovery and purity responses. Controlled 50/50 copper–plastic mixtures were prepared from pre-processed cable waste to ensure reproducible laboratory conditions, while recognizing that this feed is simplified compared with variable industrial cable-waste streams. Tests were conducted at motor speeds of 700–1200 rpm and four inclination configurations based on transverse tilt angle (α) and longitudinal tilt angle (β). The best performance within the tested experimental domain was obtained at α = 8°, β = 0°, and 1000 rpm, yielding copper recovery of 96.63% with 97.67% purity, and plastic recovery of 97.70% with 96.73% purity. Response surface regression models were developed to describe the influence of operating parameters on separation performance. Statistical analysis showed that motor speed and its quadratic term were the dominant factors, while the copper recovery model showed the strongest predictive performance. The results indicate that vibratory separation is a promising dry mechanical approach for copper–plastic separation under controlled laboratory conditions. However, further validation using real industrial feed streams, continuous feeding, dynamic vibration measurements, and energy-consumption analysis is required before broader industrial application can be confirmed.
1
A laboratory-scale vibratory separation system was evaluated for recovering copper and plastics from mechanically crushed cable waste.
2
Response surface models showed that motor speed and its quadratic term were the dominant factors affecting separation performance.
3
The best tested conditions were α = 8°, β = 0°, and 1000 rpm, achieving 96.63% copper recovery at 97.67% purity.
4
The copper recovery model had the strongest predictive performance, but industrial applicability requires validation with variable feeds, continuous operation, vibration measurements, and energy analysis.
5
Under the same optimized conditions, plastic recovery reached 97.70% with 96.73% purity.

laboratory-scale vibratory separation of copper and plastic fractions from mechanically crushed discarded cable waste

the effects of motor speed and table inclination on copper–plastic separation efficiency, recovery, and purity, including statistical modeling of these responses

Publication Details
Publication Date
2026-01-01
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Abdennour Bouziane
Farouk Benallel Boukhoulda
Amar Encadreur Tilmatine
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%