Electrorheological damper with annular ducts for seismic protection applications

Электрореологический демпфер с кольцевыми каналами для защиты от сейсмических воздействий
Nicos Makris, Scott Burton, Douglas P. Taylor
1996-10-01

Hagen–Poiseuille flowannular duct flowelectrorheological dampermultilayer neural networkseismic protection
This paper presents the design, analysis, testing and modeling of an electrorheological (ER) fluid damper developed for vibration and seismic protection of civil structures. The damper consists of a main cylinder and a piston rod that pushes an ER fluid through a stationary annular duct. The behavior of the damper can be approximated with Hagen - Poiseuille flow theory. The basic equations that describe the fluid flow across an annular duct are derived. Experimental results on the damper response with and without the presence of electric field are presented. As the rate of deformation increases, viscous stresses prevail over field-induced yield stresses and a smaller fraction of the total damper force can be controlled. Simple physically motivated phenomenological models are considered to approximate the damper response with and without the presence of electric field. Subsequently, the performance of a multilayer neural network constructed and trained by an efficient algorithm known as the Dependence Identification Algorithm is examined to predict the response of the electrorheological damper. A combination of a simple phenomenological model and a neural network is then proposed as a practical tool to approximate the nonlinear and velocity-dependent damper response.
1
A hybrid of a phenomenological model and a multilayer neural network trained with the Dependence Identification Algorithm is proposed to approximate nonlinear, velocity-dependent damper behavior.
2
An electrorheological fluid damper using a piston-driven flow through a stationary annular duct is designed for vibration and seismic protection.
3
As deformation rate increases, viscous stresses dominate field-induced yield stresses, reducing the controllable fraction of total damping force.
4
Simple phenomenological models are evaluated for damper responses with and without an applied electric field.
5
The damper’s fluid behavior can be approximated using Hagen–Poiseuille flow theory, with governing equations derived for annular-duct flow.

Electrorheological fluid damper with a stationary annular duct for vibration and seismic protection of civil structures

Nonlinear, velocity-dependent damper response and its controllability under applied electric fields, including the contributions of viscous and field-induced yield stresses and predictive modeling performance

Publication Details
Publication Date
1996-10-01
Journal
Publisher
ISSN
Cited by
41
Access Type
Author Information
Authors
Nicos Makris
Scott Burton
Douglas P. Taylor
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%