Abstract We present optical light curves, redshifts, and classifications for spectroscopically confirmed Type Ia supernovae (SNe Ia) discovered by the Pan-STARRS1 (PS1) Medium Deep Survey. We detail improvements to the PS1 SN photometry, astrometry, and calibration that reduce the systematic uncertainties in the PS1 SN Ia distances. We combine the subset of PS1 SNe Ia (0.03 < z < 0.68) with useful distance estimates of SNe Ia from the Sloan Digital Sky Survey (SDSS), SNLS, and various low- z and Hubble Space Telescope samples to form the largest combined sample of SNe Ia, consisting of a total of SNe Ia in the range of 0.01 < z < 2.3, which we call the “Pantheon Sample.” When combining Planck 2015 cosmic microwave background (CMB) measurements with the Pantheon SN sample, we find and for the w CDM model. When the SN and CMB constraints are combined with constraints from BAO and local H 0 measurements, the analysis yields the most precise measurement of dark energy to date: and for the CDM model. Tension with a cosmological constant previously seen in an analysis of PS1 and low- z SNe has diminished after an increase of 2× in the statistics of the PS1 sample, improved calibration and photometry, and stricter light-curve quality cuts. We find that the systematic uncertainties in our measurements of dark energy are almost as large as the statistical uncertainties, primarily due to limitations of modeling the low-redshift sample. This must be addressed for future progress in using SNe Ia to measure dark energy.
Key Findings
1
Combining Pantheon supernovae with Planck 2015 CMB data, and additionally BAO and local H0 constraints, produces the most precise dark-energy measurement reported at the time.
2
Improvements to PS1 photometry, astrometry, and calibration reduce systematic uncertainties in Type Ia supernova distance estimates.
3
Previously observed tension with a cosmological constant is reduced after doubling PS1 statistics, improving calibration and photometry, and applying stricter light-curve quality cuts.
4
Systematic uncertainties are nearly as large as statistical uncertainties, primarily because of limitations in modeling the low-redshift supernova sample.
5
The authors construct the Pantheon Sample by combining PS1, SDSS, SNLS, low-redshift, and Hubble Space Telescope supernovae spanning 0.01 < z < 2.3.
6
The study presents optical light curves, redshifts, and spectroscopic classifications for Type Ia supernovae from the Pan-STARRS1 Medium Deep Survey.
Research Object
Spectroscopically confirmed Type Ia supernovae (SNe Ia) and their combined Pantheon cosmological sample
Research Subject
Their calibrated light-curve distances and the resulting constraints on dark energy and cosmological parameters
Publication Details
Publication Date
2018-05-29
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai4
Planck 2015 results2016
NINE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE ( WMAP ) OBSERVATIONS: COSMOLOGICAL PARAMETER RESULTS2013
Type Ia Supernova Discoveries at z > 1 from the Hubble Space Telescope : Evidence for Past Deceleration and Constraints on Dark Energy Evolution2004
Observational Constraints on the Nature of Dark Energy: First Cosmological Results from the ESSENCE Supernova Survey2007