Performance of Airborne Imaging Spectrometers for Carbon Dioxide Detection and Emission Quantification
Эффективность бортовых изображающих спектрометров для обнаружения диоксида углерода и количественной оценки выбросов
2025-04-03
SCID: 54.1/qy4x92v3
Discuss with AI
airborne imaging spectrometersannual emission estimatescarbon dioxide emissionslognormal matched filterpoint source quantification
Figures from the paper
Abstract (AI)
Abstract Carbon dioxide (CO 2 ) emissions from strong point sources account for a significant proportion of the global greenhouse gas emissions, and their associated uncertainties in bottom‐up estimates remain substantial. Imaging spectrometers provide a capability to monitor large point source CO 2 emissions and help reduce the uncertainties. In this study, we assess the capability of an airborne monitoring system with temporally sparse observations to constrain annual emissions at both facility and regional scales. We use observations of power plant emissions from 2022 to 2023 and compare the derived emission rates at facility scale to in stack emission observations across the United States. We show that CO 2 concentration enhancements retrieved using a lognormal matched filter are suitable for CO 2 quantification, achieving low bias and uncertainty in estimated emission rates. We find that annual emissions at the regional scale can be effectively constrained by offsetting errors identified at the facility scale, with a 30% uncertainty.
Key Findings
1
A lognormal matched filter retrieves CO₂ concentration enhancements suitable for quantification, producing low bias and uncertainty in emission-rate estimates.
2
Airborne imaging spectrometers can monitor large point-source CO₂ emissions despite temporally sparse observations.
3
Facility-scale emission rates derived from 2022–2023 observations were compared with in-stack measurements from power plants across the United States.
4
Regional annual emissions can be effectively constrained by offsetting facility-scale errors, with an estimated uncertainty of 30%.
Research Object
Airborne imaging spectrometer monitoring of CO2 emissions from power plants and other strong point sources
Research Subject
The capability and accuracy of temporally sparse airborne observations for quantifying facility- and regional-scale annual CO2 emissions, including concentration-retrieval bias and uncertainty
Publication Details
Publication Date
2025-04-03
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest