Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates?

Могут ли коммерческие недорогие сенсорные платформы способствовать мониторингу качества воздуха и оценке воздействия загрязнения?
Núria Castell, Franck René Dauge, Philipp Schneider, Matthias Vogt, Uri Lerner, Barak Fishbain, David M. Broday, Alena Bartoňová
2016-12-28

citizen scienceexposure assessmentlow-cost air quality sensorsreference analyzerssensor performance evaluation
The emergence of low-cost, user-friendly and very compact air pollution platforms enable observations at high spatial resolution in near-real-time and provide new opportunities to simultaneously enhance existing monitoring systems, as well as engage citizens in active environmental monitoring. This provides a whole new set of capabilities in the assessment of human exposure to air pollution. However, the data generated by these platforms are often of questionable quality. We have conducted an exhaustive evaluation of 24 identical units of a commercial low-cost sensor platform against CEN (European Standardization Organization) reference analyzers, evaluating their measurement capability over time and a range of environmental conditions. Our results show that their performance varies spatially and temporally, as it depends on the atmospheric composition and the meteorological conditions. Our results show that the performance varies from unit to unit, which makes it necessary to examine the data quality of each node before its use. In general, guidance is lacking on how to test such sensor nodes and ensure adequate performance prior to marketing these platforms. We have implemented and tested diverse metrics in order to assess if the sensor can be employed for applications that require high accuracy (i.e., to meet the Data Quality Objectives defined in air quality legislation, epidemiological studies) or lower accuracy (i.e., to represent the pollution level on a coarse scale, for purposes such as awareness raising). Data quality is a pertinent concern, especially in citizen science applications, where citizens are collecting and interpreting the data. In general, while low-cost platforms present low accuracy for regulatory or health purposes they can provide relative and aggregated information about the observed air quality.
1
Although generally unsuitable for regulatory or health-related accuracy requirements, low-cost platforms can provide relative and aggregated information about air quality.
2
An exhaustive evaluation of 24 identical commercial low-cost sensor units compared their measurements with CEN reference analyzers across varied conditions.
3
Each sensor node requires individual data-quality assessment before deployment because platform-level performance is not uniform.
4
Sensor performance varied spatially and temporally with atmospheric composition and meteorological conditions, and also differed between individual units.
5
The study implemented metrics distinguishing suitability for high-accuracy regulatory or epidemiological applications from lower-accuracy pollution awareness and coarse-scale monitoring.

commercial low-cost air pollution sensor platforms

measurement performance and data quality across units, time, atmospheric composition, and meteorological conditions, including suitability for air-quality monitoring and exposure estimation

Publication Details
Publication Date
2016-12-28
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Núria Castell
Franck René Dauge
Philipp Schneider
Matthias Vogt
Uri Lerner
Barak Fishbain
David M. Broday
Alena Bartoňová
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%