Hybrid Transformer Model for Transient Simulation—Part I: Development and Parameters
Гибридная модель трансформатора для переходных процессов — Часть I: разработка и параметры
2007-01-01
SCID: 54.1/s7c298aa
Discuss with AI
frequency-dependent coil resistancehybrid transformer modellumped-parameter saturable corematrix leakage and capacitive effectstransient simulation
Figures from the paper
Abstract (AI)
A new topologically correct hybrid transformer model is developed for low and midfrequency transient simulations. Power transformers have a conceptually simple design, but behaviors can be very complex. The selection of the most suitable representation for a given behavior depends on the type of transformer to be simulated, the frequency range, and other factors, such as the internal design of the transformer and available parameters or design data. Here, a modular model suitable for frequencies up to 3-5 kHz is developed, utilizing a duality-based lumped-parameter saturable core, matrix descriptions of leakage and capacitive effects, and frequency-dependent coil resistance. Implementation and testing of this model was done for 15-kVA 208Delta-120Y 3-legged and 150-kVA 12,470Y-208Y 5-legged transformers. The basis and development of the model is presented, along with a discussion of necessary parameters and the approaches for obtaining them
Key Findings
1
A new topologically correct hybrid transformer model is developed for low and mid-frequency transient simulations up to 3–5 kHz.
2
Frequency-dependent coil resistance is incorporated to improve transient simulation accuracy.
3
Implementation and testing were performed on 15-kVA 208Δ-120Y 3-legged and 150-kVA 12,470Y-208Y 5-legged transformers.
4
The model is modular and combines a duality-based lumped-parameter saturable core with matrix descriptions of leakage and capacitive effects.
5
The paper presents the model development, required parameters, and approaches for obtaining those parameters.
Research Object
Topologically correct hybrid transformer model for low- and mid-frequency transient simulations (implemented for 15-kVA 208Δ-120Y 3-legged and 150-kVA 12,470Y-208Y 5-legged power transformers)
Research Subject
Development, parameterization, and implementation of a modular hybrid transformer model (dual lumped-parameter saturable core, matrix leakage/capacitance, frequency-dependent coil resistance) suitable for transient simulation up to ~3–5 kHz, and approaches to obtain necessary parameters
Publication Details
Publication Date
2007-01-01
Journal
Publisher
ISSN
Access Type
Author Information
Download PDF
Subscribe to digest