The use of sigma-delta-ADC in the commutation mode

Использование сигма-дельта АЦП в режиме коммутации
Л. Дімітров, Vadim Zhmud, Alexsey Taichenachev
2017-06-01

VisSim simulationcommutation modesigma-delta ADCswitching mode ADC
Analog-to-digital converters (ADC) in switching mode are used to convert the signals from multiple sources of the ADC means. It was considered appropriate, since it was believed that this provides a significant simplification of the hardware. Today, the advantage of hardware saving is negligible in compare with the loss of measurement accuracy because of the use of switching mode, which is unreasonably high. ADC developers still offer switching mode, include it in the realization of the circuit performance and recommends it in the user hides. This paper describes carried out comparative study of the ADC in switching mode and this without switching. This study is done with VisSim program simulation. To simulate the operating principle sigma-delta-ADC were used because such ADC are becoming more widespread due to their low cost, high accuracy and speed, sufficient for many practical cases. The simulation results substantiate the reason of non-switched regime. If, however, switching is inevitable, the paper provides recommendations to reduce the error generated by the switching.
1
A comparative study using VisSim simulations of sigma-delta ADCs shows results that substantiate preferring non-switched regime for accuracy.
2
Sigma-delta ADCs were chosen for simulation due to their low cost, high accuracy, and adequate speed for practical cases.
3
Switching mode introduces an unreasonably high loss of measurement accuracy compared to non-switched operation.
4
Using switching (commutation) mode for ADCs no longer provides significant hardware savings compared to non-switched designs.
5
When switching is unavoidable, the paper provides specific recommendations to reduce switching-induced error.

Sigma-delta analog-to-digital converter (sigma-delta ADC) operated in commutation (switching) mode

Effect of operating in switching (commutation) mode on measurement accuracy and generated switching error compared to non-switched operation, including recommendations to reduce switching-induced error (evaluated via VisSim simulation)

Publication Details
Publication Date
2017-06-01
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Л. Дімітров
Vadim Zhmud
Alexsey Taichenachev
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%