Total Knee Arthroplasty MRI Featuring Slice-Encoding for Metal Artifact Correction: Reduction of Artifacts for STIR and Proton Density–Weighted Sequences
МРТ после тотального эндопротезирования коленного сустава с применением кодирования срезов для коррекции металлических артефактов: уменьшение артефактов в последовательностях STIR и с взвешиванием по протонной плотности
2013-11-21
SCID: 54.1/shpxf88y
Discuss with AI
STIR MRIperiprosthetic osteolysisproton density-weighted imagingslice-encoding for metal artifact correctiontotal knee arthroplasty
Figures from the paper
Abstract (AI)
OBJECTIVE: The purpose of this article is to compare slice-encoding for metal artifact correction (SEMAC) sequences versus optimized standard MRI sequences in patients with total knee arthroplasty (TKA). SUBJECTS AND METHODS: Forty-two patients with TKA underwent 1.5-T MRI. Sequences optimized for metal implant imaging (SEMAC) were compared with standard sequences optimized with high bandwidth for STIR and proton density (PD)-weighted images. In 29 patients, CT was available as reference standard. Signal void and insufficient fat saturation were quantified. Qualitative criteria (anatomy, distortion, blurring, and noise) were assessed on a 5-point scale (1, no artifacts; 5, severe artifacts) by two readers. Abnormal imaging findings were noted. A Student t test and a Wilcoxon signed rank test was used for statistics. RESULTS: Signal void areas and insufficient fat saturation were smaller for the SEMAC sequences than for the optimized standard sequences (p ≤ 0.005 for all comparisons). Depiction of anatomic structures was better on STIR with SEMAC versus standard sequences optimized with high bandwidth (score range, 2.9-3.7 vs 4.2-4.9) and on PD-weighted imaging with SEMAC versus standard sequences optimized with high bandwidth (score range, 2.5-3.5 vs 3.1-3.8), which was statistically significant (p < 0.001 to p = 0.007 for different structures). Distortion and noise were lower for SEMAC than for the standard sequences (p ≤ 0.001), whereas no technique had a clear advantage for blurring. Detection of abnormal imaging findings was markedly increased for the SEMAC technique (p < 0.001) and was most pronounced for STIR images (98 and 74 findings for STIR with SEMAC for readers 1 and 2, respectively, vs 37 and 37 findings for readers 1 and 2, respectively, for STIR with standard sequences optimized with high bandwidth). Sensitivity for detection of periprosthetic osteolysis was improved for STIR with SEMAC (100% and 86% for readers 1 and 2, respectively) compared with STIR with standard sequences optimized with high bandwidth (14% and 29% for readers 1 and 2, respectively). CONCLUSION: SEMAC sequences showed a statistically significant artifact reduction. The detection of clinically relevant findings such as periprosthetic osteolysis was markedly improved.
Key Findings
1
Anatomic structures were depicted more clearly with SEMAC for STIR and proton density–weighted imaging, with statistically significant improvements across evaluated structures.
2
Detection of abnormal imaging findings was markedly higher with SEMAC, particularly for STIR, yielding 98 versus 37 findings for reader 1 and 74 versus 37 for reader 2.
3
SEMAC reduced image distortion and noise compared with standard high-bandwidth sequences, while neither technique showed a clear advantage for blurring.
4
SEMAC sequences produced significantly smaller signal-void areas and less insufficient fat saturation than high-bandwidth optimized standard sequences for both STIR and proton density–weighted MRI after total knee arthroplasty (p ≤ 0.005).
5
Sensitivity for detecting periprosthetic osteolysis improved with STIR SEMAC, reaching 100% and 86% for the two readers, respectively, compared with standard imaging.
Research Object
MRI of total knee arthroplasty patients using STIR and proton density–weighted sequences
Research Subject
Reduction of metal-related artifacts and improvement of anatomic and abnormal-finding detection with SEMAC versus optimized standard high-bandwidth MRI sequences