Novel Phenolic Biosensor Based on a Magnetic Polydopamine-Laccase-Nickel Nanoparticle Loaded Carbon Nanofiber Composite
Новый фенольный биосенсор на основе композита из углеродных нанонокон, нагруженных наночастицами никеля, полидофамином и лакказой
2014-03-07
SCID: 54.1/tmj2ampc
Discuss with AI
catechol detectiondirect electron transfernickel nanoparticle-loaded carbon nanofibersphenolic biosensorpolydopamine-laccase composite
Figures from the paper
Abstract (AI)
A novel phenolic biosensor was prepared on the basis of a composite of polydopamine (PDA)-laccase (Lac)-nickel nanoparticle loaded carbon nanofibers (NiCNFs). First, NiCNFs were fabricated by a combination of electrospinning and a high temperature carbonization technique. Subsequently, the magnetic composite was obtained through one-pot Lac-catalyzed oxidation of dopamine (DA) in an aqueous suspension containing Lac, NiCNFs, and DA. Finally, a magnetic glass carbon electrode (MGCE) was employed to separate and immobilize the composite; the modified electrode was then denoted as PDA-Lac-NiCNFs/MGCE. Fourier transform infrared (FT-IR) spectra and cyclic voltammetry (CV) analyses revealed the NiCNFs had good biocompatibility for Lac immobilization and greatly facilitated the direct electron transfer between Lac and electrode surface. The immobilized Lac showed a pair of stable and well-defined redox peaks, and the electrochemical behavior of Lac was a surface-controlled process in pH 5.5 acetate buffer solution. The PDA-Lac-NiCNFs/MGCE for biosensing of catechol exhibited a sensitivity of 25 μA mM(-1) cm(-2), a detection limit of 0.69 μM (S/N = 3), and a linear range from 1 μM to 9.1 mM, as well as good selectivity and stability. Meanwhile, this novel biosensor demonstrated its promising application in detecting catechol in real water samples.
Key Findings
1
A magnetic PDA-Lac-NiCNF composite was fabricated through one-pot laccase-catalyzed dopamine oxidation and immobilized on a magnetic glassy carbon electrode.
2
For catechol detection, the biosensor achieved 25 μA mM−1 cm−2 sensitivity, a 0.69 μM detection limit, and a 1 μM–9.1 mM linear range.
3
Immobilized laccase displayed stable, well-defined redox peaks, with electrochemical behavior governed by a surface-controlled process in pH 5.5 acetate buffer.
4
Nickel nanoparticle-loaded carbon nanofibers provided biocompatibility for laccase immobilization and facilitated direct electron transfer between laccase and the electrode.
5
The biosensor showed good selectivity and stability and successfully demonstrated catechol detection in real water samples.
Research Object
PDA-Lac-NiCNFs-modified magnetic glassy carbon electrode for catechol detection
Research Subject
Electrochemical biosensing performance, electron-transfer behavior, selectivity, stability, and real-sample detection of catechol
Publication Details
Publication Date
2014-03-07
Journal
Publisher
ISSN
Access Type
Author Information
Download PDF
Subscribe to digest