Multifilament HTS Cables to Reduce AC Loss: Proof-of-Concept Experiments and Simulation

Многониточные HTS-кабели для снижения переменных потерь: экспериментальная проверка концепции и моделирование
Min Zhang, Tian Lan, Weijia Yuan, Hengpei Liao, Muhammad Haseeb Iftikhar, Alexandre Cole, Reda Abdouh
2023-04-10

AC loss reductioncoupling lossesheat shrink tube insulationmultifilament HTS cablesrotational magnetic field measurements
Reducing ac losses of high-temperature superconducting (HTS) is essential for ac application since it can lower the constraint on the cryogenic cooling demand. Several studies have reported that the manufacturing of multifilament HTS cables can reduce ac loss. However, large coupling losses were identified in the existing cables, due to the existence of coupled copper or soldering layers. We report in this article a novel way to develop multifilament HTS cables, mainly focusing on suppressing the coupling losses by reducing the contact resistivity within the HTS cables. Heat shrink tubes are used to directly insulate narrow HTS filaments into a cable structure. Sample cables were made with 4 mm and 2 mm wide HTS strips. Both transport losses and total ac losses in a rotational magnetic field were measured to quantify the ac loss reduction for the multifilament HTS cables. The measurements were used to validate the modeling results, and to predict ac loss reduction for 1 mm wide HTS cable. The results showed loss reduction up to around 90% in the 1 mm wide HTS cable compared with 4 mm cable. As a result, the proposed multifilament HTS cables will have promising applications in reducing ac loss.
1
A novel multifilament HTS cable manufacturing approach uses heat shrink tubes to electrically insulate narrow HTS filaments, aiming to suppress coupling losses by increasing contact resistivity between filaments.
2
Measurements were used to validate simulations and to predict AC loss reduction for a 1 mm wide HTS multifilament cable.
3
Prototype cables were fabricated from 4 mm and 2 mm wide HTS strips and tested for transport losses and total AC losses in a rotational magnetic field.
4
Simulations and validated measurements indicate up to ~90% AC loss reduction for a 1 mm wide multifilament HTS cable compared with a 4 mm single-strip cable.
5
The proposed multifilament HTS cables are presented as a promising solution to lower cryogenic cooling demands in AC applications by substantially reducing AC losses.

Multifilament high-temperature superconducting (HTS) cables constructed from insulated narrow HTS strips (2 mm, 4 mm, and predicted 1 mm widths)

Reduction and characterization of AC losses (transport losses, total AC losses in a rotating magnetic field) and suppression of coupling losses via filament insulation/contact resistivity control, supported by experiments and simulations

Publication Details
Publication Date
2023-04-10
Journal
Publisher
ISSN
Cited by
6
Access Type
Author Information
Authors
Min Zhang
Tian Lan
Weijia Yuan
Hengpei Liao
Muhammad Haseeb Iftikhar
Alexandre Cole
Reda Abdouh
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%