Development of the Hearing In Noise Test for the measurement of speech reception thresholds in quiet and in noise

Разработка теста Hearing In Noise для измерения порогов восприятия речи в тишине и в шуме
Michael J. Nilsson, Sigfrid D. Soli, Jean Sullivan
1994-02-01

Hearing In Noise Testadaptive measurementphonemically balanced sentence listsspeech intelligibility in noisespeech reception thresholds
A large set of sentence materials, chosen for their uniformity in length and representation of natural speech, has been developed for the measurement of sentence speech reception thresholds (sSRTs). The mean-squared level of each digitally recorded sentence was adjusted to equate intelligibility when presented in spectrally matched noise to normal-hearing listeners. These materials were cast into 25 phonemically balanced lists of ten sentences for adaptive measurement of sentence sSRTs. The 95% confidence interval for these measurements is +/- 2.98 dB for sSRTs in quiet and +/- 2.41 dB for sSRTs in noise, as defined by the variability of repeated measures with different lists. Average sSRTs in quiet were 23.91 dB(A). Average sSRTs in 72 dB(A) noise were 69.08 dB(A), or -2.92 dB signal/noise ratio. Low-pass filtering increased sSRTs slightly in quiet and noise as the 4- and 8-kHz octave bands were eliminated. Much larger increases in SRT occurred when the 2-kHz octave band was eliminated, and bandwidth dropped below 2.5 kHz. Reliability was not degraded substantially until bandwidth dropped below 2.5 kHz. The statistical reliability and efficiency of the test suit it to practical applications in which measures of speech intelligibility are required.
1
A uniform, natural-speech sentence corpus was developed and calibrated for equal intelligibility in spectrally matched noise among normal-hearing listeners.
2
Mean sSRTs were 23.91 dB(A) in quiet and 69.08 dB(A) in 72 dB(A) noise, corresponding to a −2.92 dB signal-to-noise ratio.
3
Measurement reliability was high, with 95% confidence intervals of ±2.98 dB in quiet and ±2.41 dB in noise across repeated lists.
4
Removing the 4- and 8-kHz bands slightly increased sSRTs, whereas eliminating the 2-kHz band caused much larger increases when bandwidth fell below 2.5 kHz; reliability remained largely intact above that bandwidth.
5
The materials comprise 25 phonemically balanced lists of ten sentences, enabling adaptive measurement of sentence speech reception thresholds (sSRTs).

sentence speech reception thresholds in quiet and in spectrally matched noise for normal-hearing listeners

measurement reliability, intelligibility, and bandwidth dependence of sentence speech reception thresholds

Publication Details
Publication Date
1994-02-01
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Michael J. Nilsson
Sigfrid D. Soli
Jean Sullivan
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%