Investigation of Serratia marcescens surgical site infection outbreak associated with peroperative ultrasonography probe
Расследование вспышки инфекций области хирургического вмешательства, вызванных Serratia marcescens и связанной с периоперационным ультразвуковым датчиком
2021-02-15
SCID: 54.1/wv8pd7fv
Discuss with AI
Serratia marcescensgenomic epidemiologyintraoperative ultrasonography probeoutbreak investigationsurgical site infection
Figures from the paper
Abstract (AI)
Early postoperative infections due to Serratia marcescens have been reported by both clinicians and microbiologists in our teaching hospital. Here, we present an interlinked clinical, epidemiological, environmental and genomic investigation of this outbreak due to a T-shaped intraoperative probe contaminated by S. marcescens used during peroperative ultrasonography in laparoscopic liver resection.
Key Findings
1
A contaminated T-shaped intraoperative ultrasonography probe was identified as the outbreak source.
2
An outbreak of early postoperative Serratia marcescens surgical-site infections occurred in a teaching hospital.
3
The investigation integrated clinical, epidemiological, environmental, and genomic analyses to characterize the outbreak.
4
The probe had been used during peroperative ultrasonography in laparoscopic liver resection, linking the device to infection transmission.
Research Object
Serratia marcescens surgical site infection outbreak associated with a contaminated T-shaped intraoperative ultrasonography probe used during laparoscopic liver resection
Research Subject
The clinical, epidemiological, environmental, and genomic characteristics and source transmission of the outbreak
Publication Details
Publication Date
2021-02-15
Journal
Publisher
ISSN
Cited by
18
Open access PDF
Access Type
Author Information
Download PDF