Friction and Wear of Hard Yet Tough TiN Coatings Deposited Using High-Power Impulse Magnetron Sputtering
Трение и износ твердых, но вязких TiN-покрытий, нанесенных методом импульсного магнетронного распыления высокой мощности
2024-05-10
SCID: 54.1/xf3pdmup
Discuss with AI
TiN coatingsabrasive wearfracture toughnessfriction and wearhigh-power impulse magnetron sputtering
Figures from the paper
Abstract (AI)
The friction and wear response of hard coatings is complex, which largely depends on a good combination of hardness and toughness, and their service life is difficult to predict. Hence, in this work, hard yet tough TiN coatings were deposited using high-power impulse magnetron sputtering at 5–10 kW. With increasing sputtering power, the coatings showed a transition in crystal texture from (200) to (111), along with a refinement in microstructure, leading to an improvement in hardness (H) of 29.8–31.2 GPa and an effective Young’s modulus (E*) of 310–365 GPa. The hard yet tough TiN coatings deposited at 6.5 kW exhibited the highest H/E* and H3/E*2 ratios of 0.097 and 0.29, respectively, as well as the highest fracture toughness of 2.1 MPa·m1/2 and elastic recovery of 42.5%. Accordingly, the coatings possessed an enhanced adhesion and cohesion, in terms of micro-scratch critical load (LC3 = 19.67 N) and HF Rockwell HF1 level. The friction and wear response of hard yet tough TiN coatings under the normal load of 1–10 N were investigated to explore their durability and predict their critical load up to failure. Wear mechanisms changed from oxidative to severe abrasive wear, with load increasing from 1 to 10 N. At 2–5 N, a combination of oxidative and abrasive wear was observed. The coatings maintained their integrity up to the critical load of 9.4 N before failure event, with a maximum wear track depth of 1.8 μm, indicating their durability under the loading conditions.
Key Findings
1
High-power impulse magnetron sputtering produced hard yet tough TiN coatings with hardness of 29.8–31.2 GPa and effective Young’s modulus of 310–365 GPa.
2
Increasing sputtering power transformed the crystal texture from (200) to (111) and refined the coating microstructure.
3
The coatings retained integrity up to a critical failure load of 9.4 N, with a maximum wear-track depth of 1.8 μm, demonstrating durability under the tested loads.
4
The optimized coating showed enhanced adhesion and cohesion, with a micro-scratch critical load of 19.67 N and HF1 Rockwell adhesion level.
5
TiN deposited at 6.5 kW achieved optimal toughness-related properties, including H/E* = 0.097, H³/E*² = 0.29, fracture toughness of 2.1 MPa·m¹ᐟ², and elastic recovery of 42.5%.
6
Wear mechanisms progressed from oxidative wear at low loads to combined oxidative–abrasive wear at 2–5 N and severe abrasive wear at 10 N.
Research Object
Hard yet tough TiN coatings deposited by high-power impulse magnetron sputtering
Research Subject
The friction, wear mechanisms, mechanical properties, adhesion, cohesion, durability, and failure critical load of the TiN coatings under normal loads of 1–10 N
Publication Details
Publication Date
2024-05-10
Journal
Publisher
ISSN
Cited by
11
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest