The rib cage stabilizes the human thoracic spine: An in vitro study using stepwise reduction of rib cage structures
Грудная клетка стабилизирует грудной отдел позвоночника человека: исследование in vitro с поэтапным удалением структур грудной клетки
2017-06-01
SCID: 54.1/ykf6kk7g
Discuss with AI
neutral zonerange of motionrib cage biomechanicsstepwise rib cage reductionthoracic spine stability
Figures from the paper
Abstract (AI)
The stabilizing effect of the rib cage on the human thoracic spine is still not sufficiently analyzed. For a better understanding of this effect as well as the calibration and validation of numerical models of the thoracic spine, experimental biomechanics data is required. This study aimed to determine (1) the stabilizing effect of the single rib cage structures on the human thoracic spine as well as the effect of the rib cage on (2) the flexibility of the single motion segments and (3) coupled motion behavior of the thoracic spine. Six human thoracic spine specimens including the entire rib cage were loaded quasi-statically with pure moments of ± 2 Nm in flexion/extension (FE), lateral bending (LB), and axial rotation (AR) using a custom-built spine tester. Motion analysis was performed using an optical motion tracking system during load application to determine range of motion (ROM) and neutral zone (NZ). Specimens were tested (1) in intact condition, (2) after removal of the intercostal muscles, (3) after median sternotomy, after removal of (4) the anterior rib cage up to the rib stumps, (5) the right sixth to eighth rib head, and (6) all rib heads. Significant (p < 0.05) increases of the ROM were found after dissecting the intercostal muscles (LB: + 22.4%, AR: + 22.6%), the anterior part of the rib cage (FE: + 21.1%, LB: + 10.9%, AR: + 72.5%), and all rib heads (AR: + 5.8%) relative to its previous condition. Compared to the intact condition, ROM and NZ increased significantly after removing the anterior part of the rib cage (FE: + 52.2%, + 45.6%; LB: + 42.0%, + 54.0%; AR: + 94.4%, + 187.8%). Median sternotomy (FE: + 11.9%, AR: + 21.9%) and partial costovertebral release (AR: + 11.7%) significantly increased the ROM relative to its previous condition. Removing the entire rib cage increased both monosegmental and coupled motion ROM, but did not alter the qualitative motion behavior. The rib cage has a strong effect on thoracic spine rigidity, especially in axial rotation by a factor of more than two, and should therefore be considered in clinical scenarios, in vitro, and in silico.
Key Findings
1
Anterior rib-cage removal increased neutral-zone motion by 45.6% in flexion/extension, 54.0% in lateral bending, and 187.8% in axial rotation.
2
Removing intercostal muscles increased range of motion by 22.4% in lateral bending and 22.6% in axial rotation.
3
Removing the anterior rib cage increased ROM relative to intact specimens by 52.2% in flexion/extension, 42.0% in lateral bending, and 94.4% in axial rotation.
4
Removing the entire rib cage increased both monosegmental and coupled-motion ROM but did not change qualitative thoracic motion behavior.
5
The rib cage substantially stabilizes the human thoracic spine, with its strongest effects observed in axial rotation.
Research Object
the human thoracic spine with its rib cage
Research Subject
the rib cage’s stabilizing effect on thoracic spine rigidity, segmental flexibility, and coupled motion behavior
Publication Details
Publication Date
2017-06-01
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest