Knowledge about the optical properties μa,μs, and g of human blood plays an important role for many diagnostic and therapeutic applications in laser medicine and medical diagnostics. They strongly depend on physiological parameters such as oxygen saturation, osmolarity, flow conditions, haematocrit, etc. The integrating sphere technique and inverse Monte Carlo simulations were applied to measure μa,μs, and g of circulating human blood. At 633 nm the optical properties of human blood with a haematocrit of 10% and an oxygen saturation of 98% were found to be 0.210±0.002 mm-1 for μa,77.3±0.5 mm-1 for μs, and 0.994±0.001 for the g factor. An increase of the haematocrit up to 50% lead to a linear increase of absorption and reduced scattering. Variations in osmolarity and wall shear rate led to changes of all three parameters while variations in the oxygen saturation only led to a significant change of the absorption coefficient. A spectrum of all three parameters was measured in the wavelength range 400-2500 nm for oxygenated and deoxygenated blood, showing that blood absorption followed the absorption behavior of haemoglobin and water. The scattering coefficient decreased for wavelengths above 500 nm with approximately λ-1.7; the g factor was higher than 0.9 over the whole wavelength range. © 1999 Society of Photo-Optical Instrumentation Engineers.
1
Across 400–2500 nm, absorption followed haemoglobin and water spectra; scattering decreased approximately as λ⁻¹·⁷ above 500 nm, while g remained above 0.9.
2
At 633 nm, blood with 10% haematocrit and 98% oxygen saturation had μa = 0.210 ± 0.002 mm⁻¹, μs = 77.3 ± 0.5 mm⁻¹, and g = 0.994 ± 0.001.
3
Changes in osmolarity and wall shear rate altered all three optical parameters, whereas oxygen saturation significantly affected only absorption.
4
Increasing haematocrit to 50% caused a linear increase in absorption and a reduction in scattering.
5
Integrating-sphere measurements combined with inverse Monte Carlo simulations quantified absorption, scattering, and anisotropy of circulating human blood.

circulating human blood

wavelength-dependent optical properties (absorption coefficient μa, scattering coefficient μs, and anisotropy factor g) and their dependence on haematocrit, oxygen saturation, osmolarity, and flow conditions

Publication Details
Publication Date
1999-01-01
Journal
Publisher
ISSN
Cited by
811
Access Type
Author Information
Authors
Andreas Hahn
A. Roggan
M.F. Friebel
K. Dörschel
G. Müller
Andreas Hahn
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%