Carbon Content and Grain Size Effects on the Sensitization of AISI Type 304 Stainless Steels

Влияние содержания углерода и размера зерна на сенсибилизацию нержавеющих сталей AISI типа 304
R. Pascali, A. Benvenuti, D. F. Wenger
1984-01-01

AISI 304 austenitic stainless steelASTM A262 Practice EEPR testcarbon contentdesensitizationgrain sizesensitization kineticssensitization temperature TKtemperature range 600–800°C
The sensitization domains of three AISI 304 austenitic stainless steels, differing only by their carbon content or grain size, have been determined using the ASTM A 262 Practice E and the EPR tests, in order to study the carbon content and grain size effects on sensitization kinetics in the temperature range 600 to 800 C. It has been found that increasing the grain size delays the beginning of the sensitization at the lower temperature considered in this study (600 C) and considerably delays desensitization. Decreasing the carbon content lowers the maximum temperature for sensitization (TK), but the discrepancies found between the results of the above-mentioned tests did not allow any other conclusion. As a consequence, the performance of these two tests has been compared, but some disagreements remain unexplained.
1
Comparison of the two test methods revealed unexplained disagreements in their performance for assessing sensitization.
2
Decreasing carbon content lowers the maximum temperature for sensitization (TK).
3
Increasing grain size delays the onset of sensitization at 600°C and considerably delays desensitization.
4
Results from ASTM A262 Practice E and EPR tests show discrepancies that prevent further conclusions about carbon content effects.
5
Sensitization domains for three AISI 304 steels (varying only in carbon content or grain size) were determined using ASTM A262 Practice E and EPR tests between 600–800°C.

Three AISI 304 austenitic stainless steels differing in carbon content or grain size

Effects of carbon content and grain size on sensitization kinetics and sensitization/desensitization behavior (sensitization domains) assessed by ASTM A262 Practice E and EPR tests between 600 and 800 °C

Publication Details
Publication Date
1984-01-01
Journal
Publisher
ISSN
Access Type
Author Information
Authors
R. Pascali
A. Benvenuti
D. F. Wenger
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%