The fire safety of lithium-ion battery systems in electric vehicles is often examined through separate studies of thermal runaway, propagation, early warning, and fire suppression, making it difficult to translate fragmented evidence into system-level protection decisions. This review critically synthesizes experimental, modeling, and full-scale evidence along the accident sequence from initiating abuse to post-suppression recovery. Thermal, electrical, gas, pressure, venting, ignition, and heat-release indicators are interpreted according to the physical events they represent, showing that reported “thermal-runaway onset” criteria are meaningful only when the diagnostic event and test boundary are defined. Evidence from cells, modules, packs, and complete vehicles is organized according to its scale-dependent explanatory role and transfer limits rather than treated as a simple hierarchy of increasing evidentiary strength. Protection measures are evaluated as coordinated preventive, detection-and-isolation, propagation-control, consequence-mitigation, and recovery barriers. The revised framework further accounts for coupling among battery packaging, thermal management, electrical architecture, structural protection, and emergency access, together with trade-offs among safety, energy density, mass, energy consumption, complexity, and cost. Barrier effectiveness is assessed according to the hazardous transition prevented or delayed, the intervention time created, the possibility of common dependencies, and the residual hazards remaining after activation. The resulting risk-informed framework connects accident escalation, safety barriers, vehicle-level system interactions, validation scale, and feedback from recovery to design refinement. The appropriate endpoint of EV battery fire protection is therefore not flame extinction alone, but a verifiably stable condition in which residual thermal, electrical, gas-related, and environmental hazards remain controllable throughout recovery.
1
Barrier performance should be judged by the hazardous transition prevented or delayed, intervention time created, common dependencies, and residual hazards after activation.
2
Cell-, module-, pack-, and vehicle-scale evidence has distinct explanatory roles and transfer limitations rather than forming a simple hierarchy of evidence strength.
3
Effective protection requires coordinated preventive, detection-and-isolation, propagation-control, consequence-mitigation, and recovery barriers.
4
Reported thermal-runaway onset criteria are interpretable only when the measured diagnostic event and experimental boundary are explicitly defined.
5
The proposed risk-informed endpoint extends beyond flame extinction to a verifiably stable state with controllable residual thermal, electrical, gas-related, and environmental hazards.
6
The review integrates evidence across thermal runaway, propagation, warning, suppression, and recovery into a system-level EV battery fire-protection framework.

Lithium-ion battery systems in electric vehicles

Cross-scale fire hazards, accident escalation, and risk-informed protection effectiveness across the battery fire sequence

Publication Details
Publication Date
2026-10-17
Journal
Applied Sciences
Publisher
Multidisciplinary Digital Publishing Institute
ISSN
2076-3417
Cited by
0
Access Type
Author Information
Authors
Liwei Zhang
Shimin Liu
Xuebao Wang
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%