Full-scale experimental study of the characteristics of electric vehicle fires process and response measures
Полномасштабное экспериментальное исследование характеристик пожаров электромобилей и мер реагирования
2023-12-11
SCID: 54.1/tawh2tvt
Discuss with AI
compressed air foamelectric vehicle firesfire suppressionfull-scale fire experimentthermal runaway
Figures from the paper
Abstract (AI)
Fire accidents are a source of concern for electric vehicles (EV). The spread of fire caused by thermal runaway (TR) in a scenario with a high concentration of EVs can result in a serious disaster. In this study, a full-scale EV fire experiment was conducted using thermal abuse to investigate response strategies to EV fires caused by TR. The pattern of TR fires spreading in EV was also investigated. The suppression capabilities of fire blankets, water spray, and compressed air foam on EV fires in the early stages were analyzed. During the test, the temperature distributions inside and outside the vehicle were measured. The maximum temperature recorded in the passenger compartment near the roof was 919.7 °C. The length of the jet flow was estimated from the images, with the longest being approximately 2.56 m. The fire suppression test demonstrated that the fire blankets effectively extinguished flames, and the temperature inside the car gradually decreased. A water mist device can reduce temperature and put out flames. The compressed air foam effectively extinguished the fire, with an average cooling rate of −9.8 °C/s. These results provide information on EV fire response strategies.
Key Findings
1
A full-scale thermal-abuse experiment characterized thermal-runaway fire propagation and response strategies for electric vehicles.
2
Compressed-air foam effectively extinguished the fire, achieving an average cooling rate of −9.8 °C/s.
3
Fire blankets effectively extinguished EV flames and caused the vehicle’s interior temperature to decrease gradually.
4
The maximum passenger-compartment temperature near the roof reached 919.7 °C, while the longest observed fire jet was approximately 2.56 m.
5
Water mist reduced temperatures and extinguished flames during the early stages of the EV fire.
Research Object
full-scale electric vehicle fires caused by thermal runaway
Research Subject
thermal runaway fire-spread characteristics, temperature distribution, and early-stage suppression effectiveness of fire blankets, water spray, and compressed air foam
Publication Details
Publication Date
2023-12-11
Journal
Case Studies in Thermal Engineering
Publisher
Elsevier BV
ISSN
2214-157X
Cited by
52
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest