Long Distance Continuous Methane Emissions Monitoring with Dual Frequency Comb Spectroscopy: deployment and blind testing in complex emissions scenarios
Непрерывный мониторинг выбросов метана на больших расстояниях методом двухчастотной гребенчатой спектроскопии: внедрение и слепое тестирование в условиях сложных сценариев выбросов
2020-09-22
SCID: 54.1/4ch6bvku
Discuss with AI
atmospheric modeling and inversionblind testingdual frequency comb spectroscopymethane emissions monitoringoil and gas infrastructure
Figures from the paper
Abstract (AI)
Continuous monitoring of oil and gas infrastructure is of interest for improving emissions and safety by enabling rapid identification and repair of emission sources, especially large sources that are responsible for the bulk of total emissions. We have previously demonstrated dual frequency comb spectroscopy (DCS) coupled with atmospheric modeling and inversion techniques (the DCS Observing System) as a viable and accurate approach for detection, attribution and quantification of methane emissions at distances of more than 1 km under controlled, steady emissions scenarios. Here, we present the results of validation testing designed to mimic the complexity of operational well pad emissions from oil and gas production, and the first field measurements at an active oil and gas facility. The validation tests are performed single-blind (the measurement and data analysis team are not given information about the emissions) at the Methane Emissions Technology Evaluation Center (METEC) test facility. They consist of a series of scenarios ranging from a single, steady-rate emission point to multiple emission points that include intermittent releases (the METEC "R2" tests). Additionally, we present field measurements at an active natural gas storage facility demonstrating that the system can remotely and autonomously monitor methane emissions in a true industrial setting. This field verification is in a configuration designed for continuous and long-term characterization of operational and fugitive emissions. These demonstrations confirm that the DCS Observing System can provide high-confidence continuous monitoring of emissions from complex, operational facilities among natural gas infrastructure.
Key Findings
1
Field measurements used a configuration intended for continuous, long-term characterization of operational and fugitive emissions.
2
Single-blind METEC tests covered steady single-point releases, multiple sources, and intermittent emissions representative of oil and gas well pads.
3
The DCS Observing System was validated for detecting, attributing, and quantifying methane emissions in complex operational scenarios.
4
The demonstrations support high-confidence continuous monitoring of complex emissions from natural gas infrastructure at distances exceeding 1 km.
5
The system demonstrated remote, autonomous methane monitoring at an active natural gas storage facility under true industrial conditions.
Research Object
Methane emissions from oil and gas infrastructure, including well pads and active natural gas facilities
Research Subject
Remote continuous detection, attribution, quantification, and long-term characterization of complex operational and fugitive methane emissions under steady and intermittent multi-source scenarios
Publication Details
Publication Date
2020-09-22
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF