Backstepping Model Predictive Controller for Blood Glucose Regulation in Type-I Diabetes Patient

Регулятор на основе прогнозирующего управления с моделью и бэкстеппингом для регулирования уровня глюкозы в крови у пациентов с сахарным диабетом 1 типа
Pravat Kumar Rout, Akshaya Kumar Patra, Alok Kumar Mishra
2018-07-18

backstepping model predictive controlblood glucose regulationinsulin injection controllinearized state-space modeltype-I diabetes mellitus
A robust method for optimal insulin injection as an accurate remedial measure has been focused to design since early three decades. This paper presents a novel approach to regulate the blood glucose (BG) based on backstepping model predictive controller (BMPC) for type-I diabetes mellitus (TIDM) patients. To implement the proposed approach BMPC, initially a linearized state-space model is derived from the non-linear TIDM patient with micro-insulin dispenser (MID). Through necessary simulation in MATLAB/SIMULINK platform, the proposed approach is verified and the results are presented to demonstrate its accuracy, stability, and robustness. The comparative results are presented with other suggested methods by various researchers in recent times. The results obtained under various physiological conditions with regards to meal, exercise, and uncertainties due to noise reveal the enhanced performance of the approach to control the BG level within the range of normoglycaemia (70–120 mg/dl).
1
A backstepping model predictive controller (BMPC) is proposed for regulating blood glucose in type-I diabetes patients.
2
Comparisons with recently proposed methods demonstrate enhanced control performance for the proposed approach.
3
MATLAB/SIMULINK simulations indicate that BMPC provides accurate, stable, and robust blood-glucose control.
4
The approach uses a linearized state-space model derived from a nonlinear diabetes patient model coupled with a micro-insulin dispenser.
5
Under meal intake, exercise, and noise-related uncertainty, BMPC maintains glucose within the normoglycaemic range of 70–120 mg/dl.

Type-I diabetes mellitus patients with a micro-insulin dispenser, modeled as a nonlinear blood-glucose–insulin system

Blood-glucose regulation through optimal insulin injection, including control accuracy, stability, robustness, and maintenance of normoglycaemia under meals, exercise, and measurement noise

Publication Details
Publication Date
2018-07-18
Journal
Publisher
ISSN
Cited by
37
Access Type
Author Information
Authors
Pravat Kumar Rout
Akshaya Kumar Patra
Alok Kumar Mishra
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%