Abstract (AI)
Background: Diabetes mellitus (DM) is a common chronic disease with various complications. About 10% of the world’s population suffers from this disease. For smart control of the blood glucose in DM patients, an artificial pancreas was designed and simulated by a predictive sliding mode controller considering the time delay of insulin effect. Methods: In this method, one of the time-delay glucose-insulin models was first selected. Then, using the predictive sliding mode control model, the stability of the blood glucose and insulin concentration was considered as the target. The performance and efficiency of the design were then verified by simulating the parameters of the proposed model in MATLAB software. Results: Using the proposed method, despite considering a 25-minute delay from insulin injection to its effect, the glucose and insulin concentrations reached stability in 60 and 50 minutes, respectively. Conclusion: The results of this study indicate that the combined controller of the predictive sliding mode model control can control blood glucose more effectively than previous controllers and therefore can help reduce disease complications, improve patients’ quality of life, and reduce costs and individual and health systems.
Key Findings
1
An artificial pancreas was designed using predictive sliding mode control while explicitly accounting for insulin action delay.
2
Despite a 25-minute delay between insulin injection and effect, glucose concentration stabilized within 60 minutes and insulin concentration within 50 minutes.
3
The authors report more effective blood-glucose control than previous controllers, with potential to reduce complications, improve quality of life, and lower healthcare costs.
4
The controller was evaluated with a time-delay glucose–insulin model through MATLAB simulations targeting stable glucose and insulin concentrations.
Research Object
artificial pancreas system for diabetic patients, modeled by a time-delay glucose–insulin system
Research Subject
stability and control performance of blood-glucose and insulin concentrations under a 25-minute insulin-effect delay