Studying the Synergistic Effects of Molecularly Imprinted Orthophenylenediamine and MXene / COOH ‐ MWCNT Composite for Vitro Diagnosis of Bilirubin in Human Serum

Исследование синергетических эффектов молекулярно импринтированного орто-фенилендиамина и композита MXene/COOH–MWCNT для диагностики билирубина in vitro в сыворотке крови человека
Manoj, Aditya Sharma Ghrera
2025-01-06

MXene/COOH-MWCNT compositebilirubin detectionelectrochemical detectionhuman serummolecularly imprinted sensor
ABSTRACT In this work, a molecularly imprinted sensor based on a composite of Ti3C2Tx (MXene) and carboxyl functionalized multiwall carbon nanotubes (COOH‐MWCNT) is prepared for bilirubin (BR) detection in human serum. The surface morphology and structure of the synthesized composite are characterized via field emission scanning electron microscopy (FESEM) along with elemental dispersive X‐ray analysis (EDX) and X‐ray diffraction (XRD). The formation of the BR imprint is confirmed via FESEM, atomic force microscopy (AFM), and electrochemical methods such as cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectrometry (EIS) under optimized experimental parameters. The BR imprinted electrode is prepared on the MXene/COOH‐MWCNT composite‐modified electrode by using CV in 6 mM ortho‐phenylenediamine (o‐PD) containing 2 mM BR in sodium acetate buffer solution (pH 5, 0.1 M). The linear range, limit of detection (LOD) and sensitivity are calculated as 0.1–20 mg/dL, 0.002 mg/dL, and 11.7 μA μM−1 cm−2, respectively. In addition, selectivity, reusability, reproducibility, and stability studies are performed on the prepared electrode.
1
A molecularly imprinted electrochemical sensor combining Ti3C2Tx MXene and carboxylated MWCNTs was developed for bilirubin detection in human serum.
2
Bilirubin imprinting was achieved by electropolymerizing ortho-phenylenediamine on the MXene/COOH-MWCNT-modified electrode under optimized conditions.
3
Composite morphology, structure, and imprint formation were characterized using FESEM, EDX, XRD, AFM, CV, DPV, and EIS.
4
The prepared electrode was evaluated for selectivity, reusability, reproducibility, and stability in addition to analytical performance.
5
The sensor detects bilirubin across 0.1–20 mg/dL, with a 0.002 mg/dL limit of detection and sensitivity of 11.7 μA μM−1 cm−2.

The molecularly imprinted MXene/COOH-MWCNT composite electrode for bilirubin detection in human serum

Bilirubin sensing performance, including detection range, limit of detection, sensitivity, selectivity, reusability, reproducibility, and stability

Publication Details
Publication Date
2025-01-06
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Manoj
Aditya Sharma Ghrera
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%