Electrochemical Sensor for Bilirubin Detection Using Screen Printed Electrodes Functionalized with Carbon Nanotubes and Graphene

Электрохимический сенсор для определения билирубина с использованием трафаретно-печатных электродов, функционализированных углеродными нанотрубками и графеном
Olivier J. F. Martin, Christian Santschi, Madasamy Thangamuthu, Willimann Gabriel
2018-03-07

bilirubin detectionelectrochemical sensorgraphenemulti-walled carbon nanotubesscreen-printed electrodes
Practice oriented point-of-care diagnostics require easy-to-handle, miniaturized, and low-cost analytical tools. In a novel approach, screen printed carbon electrodes (SPEs), which were functionalized with nanomaterials, are employed for selective measurements of bilirubin, which is an important biomarker for jaundice. Multi-walled carbon nanotubes (MWCNT) and graphene separately deposited on SPEs provide the core of an electrochemical sensor for bilirubin. The electrocatalytic activity towards bilirubin oxidation (bilirubin to biliverdin) was observed at +0.25 V. In addition, a further peak corresponding to the electrochemical conversion of biliverdin into purpurin appeared at +0.48 V. When compared to MWCNT, the graphene type shows a 3-fold lower detection limit (0.3 ± 0.022 nM and 0.1 ± 0.018 nM, respectively), moreover, the graphene type exhibits a larger linear range (0.1–600 µM) than MWCNT (0.5–500 µM) with a two-fold better sensitivity, i.e., 30 nA µM−1 cm−2, and 15 nA µM−1 cm−2, respectively. The viability is validated through measurements of bilirubin in blood serum samples and the selectivity is ensured by inhibiting common interfering biological substrates using an ionic nafion membrane. The presented approach enables the design and implementation of low cost and miniaturized electrochemical sensors.
1
Bilirubin oxidation to biliverdin occurs at +0.25 V, while a second peak at +0.48 V corresponds to biliverdin conversion into purpurin.
2
Graphene provides a broader linear range (0.1–600 µM versus 0.5–500 µM) and twice the sensitivity of MWCNTs: 30 versus 15 nA µM−1 cm−2.
3
Graphene-functionalized electrodes achieve a lower detection limit than MWCNT electrodes: 0.1 ± 0.018 nM versus 0.3 ± 0.022 nM.
4
Screen-printed carbon electrodes functionalized with MWCNTs or graphene enable selective electrochemical detection of bilirubin for low-cost, miniaturized diagnostics.
5
The sensor’s practical viability was demonstrated in blood serum, while an ionic Nafion membrane improved selectivity by suppressing common interfering biological substrates.

Screen-printed carbon electrodes functionalized with multi-walled carbon nanotubes or graphene for bilirubin sensing

Electrochemical bilirubin detection performance, including electrocatalytic oxidation, detection limits, linear ranges, sensitivity, and selectivity in serum samples

Publication Details
Publication Date
2018-03-07
Journal
Publisher
ISSN
Cited by
98
Access Type
Author Information
Authors
Olivier J. F. Martin
Christian Santschi
Madasamy Thangamuthu
Willimann Gabriel
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%