Bilirubin Biosensing by Using of Catalase and ZnS Nanoparticles as Modifier

Биосенсирование билирубина с использованием каталазы и наночастиц ZnS в качестве модификатора
Hamideh Dehghani, Shahrzad Khoramnejadian, Mohammad Mahboubi, Masoomeh Sasani, S. Ghobadzadeh, Saghar Mowlazadeh Haghighi, Masoud Negahdary
2016-01-01

ZnS nanoparticlesbilirubin biosensorbioelectrochemical measurementcatalasecyclic voltammetry
To find a stable bilirubin biosensor we used of catalase and Zns nanoparticles (Nps); the detection of bilirubin in this research designed on Bioelectrochemical measurement cyclic voltammetry (CV) techniques. ZnS Nanoparticles synthesized and investigated by X-Ray diffraction (XRD), UV-Visible (UV-VIS) and scanning electron microscopy (SEM). The redox peaks studied in the range of +0.5 to -0.5 V and formal potential (E°) calculated as 40 mv; also ΔEp =70 mV. In this research the anodic peak current of showed a linear relationship for different concentrations of bilirubin in the range of 3 to 50 μM. The linear equation was expressed as ipa (μA) = -0.1417-0.3661 (μM) (R2= 0.9885) with a detection limit of 2 μM for this research. The optimum pH effect was 7.0 and maximum temperature response was around 25 °C. Interference agents not showed a significant effect on this bilirubin biosensor.
1
A bilirubin biosensor was developed using catalase and ZnS nanoparticles, with detection based on cyclic voltammetric bioelectrochemical measurements.
2
Anodic peak current was linear with bilirubin concentration from 3 to 50 μM, achieving R² = 0.9885 and a detection limit of 2 μM.
3
Optimal biosensor performance occurred at pH 7.0 and approximately 25 °C, while tested interfering agents had no significant effect.
4
The biosensor exhibited redox behavior with a formal potential of 40 mV and a peak separation of 70 mV over +0.5 to −0.5 V.
5
ZnS nanoparticles were synthesized and characterized using X-ray diffraction, UV-visible spectroscopy, and scanning electron microscopy.

Catalase- and ZnS-nanoparticle-modified bilirubin biosensor

Electrochemical bilirubin detection performance, including redox response, linear concentration dependence, detection limit, pH and temperature effects, and interference resistance

Publication Details
Publication Date
2016-01-01
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Hamideh Dehghani
Shahrzad Khoramnejadian
Mohammad Mahboubi
Masoomeh Sasani
S. Ghobadzadeh
Saghar Mowlazadeh Haghighi
Masoud Negahdary
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%