Cuffless Blood Pressure Measurement
Бесманжетное измерение артериального давления
2022-04-01
SCID: 54.1/ayskfhtr
Discuss with AI
cuffless blood pressure measurementcuffless oscillometryfacial video processingpulse transit time (PTT)pulse wave analysis
Figures from the paper
Abstract (AI)
Cuffless blood pressure (BP) measurement has become a popular field due to clinical need and technological opportunity. However, no method has been broadly accepted hitherto. The objective of this review is to accelerate progress in the development and application of cuffless BP measurement methods. We begin by describing the principles of conventional BP measurement, outstanding hypertension/hypotension problems that could be addressed with cuffless methods, and recent technological advances, including smartphone proliferation and wearable sensing, that are driving the field. We then present all major cuffless methods under investigation, including their current evidence. Our presentation includes calibrated methods (i.e., pulse transit time, pulse wave analysis, and facial video processing) and uncalibrated methods (i.e., cuffless oscillometry, ultrasound, and volume control). The calibrated methods can offer convenience advantages, whereas the uncalibrated methods do not require periodic cuff device usage or demographic inputs. We conclude by summarizing the field and highlighting potentially useful future research directions.
Key Findings
1
Calibrated methods offer convenience advantages but require calibration, while uncalibrated methods avoid periodic cuff use and demographic inputs.
2
Cuffless blood pressure measurement is an active, growing field driven by clinical need and advances in smartphone and wearable sensing technology.
3
Cuffless methods fall into calibrated approaches (pulse transit time, pulse wave analysis, facial video processing) and uncalibrated approaches (cuffless oscillometry, ultrasound, volume control).
4
No cuffless BP method has yet achieved broad acceptance despite extensive ongoing research.
5
The review identifies gaps in evidence across major methods and highlights future research directions to accelerate development and application.
Research Object
Cuffless blood pressure measurement methods and systems
Research Subject
Evaluation and comparison of principles, calibrated and uncalibrated techniques (e.g., pulse transit time, pulse wave analysis, facial video processing, cuffless oscillometry, ultrasound, volume control), their evidence, advantages, limitations, and potential for clinical application
Publication Details
Publication Date
2022-04-01
Journal
Publisher
ISSN
Cited by
175
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai2
Cited by3
Photoplethysmography in Wearable Devices: A Comprehensive Review of Technological Advances, Current Challenges, and Future Directions2023
The 2023 wearable photoplethysmography roadmap2023
BP3: Improving Cuff-less Blood Pressure Monitoring Performance by Fusing mmWave Pulse Wave Sensing and Physiological Factors2024