Insulin Patch Pumps: Their Development and Future in Closed-Loop Systems

Инсулиновые помпы-пластыри: разработка и перспективы в системах с замкнутым контуром
Henry Anhalt, Nancy J.V. Bohannon
2010-06-01

artificial pancreasclosed-loop glucose controlinsulin patch pumpsmodel predictive controltype 1 diabetes mellitus
Steady progress is being made toward the development of a so-called "artificial pancreas," which may ultimately be a fully automated, closed-loop, glucose control system comprising a continuous glucose monitor, an insulin pump, and a controller. The controller will use individualized algorithms to direct delivery of insulin without user input. A major factor propelling artificial pancreas development is the substantial incidence of-and attendant patient, parental, and physician concerns about-hypoglycemia and extreme hyperglycemia associated with current means of insulin delivery for type 1 diabetes mellitus (T1DM). A successful fully automated artificial pancreas would likely reduce the frequency of and anxiety about hypoglycemia and marked hyperglycemia. Patch-pump systems ("patch pumps") are likely to be used increasingly in the control of T1DM and may be incorporated into the artificial pancreas systems of tomorrow. Patch pumps are free of tubing, small, lightweight, and unobtrusive. This article describes features of patch pumps that have been approved for U.S. marketing or are under development. Included in the review is an introduction to control algorithms driving insulin delivery, particularly the two major types: proportional integrative derivative and model predictive control. The use of advanced algorithms in the clinical development of closed-loop systems is reviewed along with projected next steps in artificial pancreas development.
1
Artificial pancreas development is motivated by the substantial incidence of hypoglycemia and extreme hyperglycemia associated with current insulin-delivery methods for type 1 diabetes.
2
Fully automated artificial pancreas systems would integrate continuous glucose monitoring, insulin pumps, and individualized control algorithms to deliver insulin without user input.
3
Successful closed-loop glucose control could reduce both the frequency of hypoglycemia and marked hyperglycemia and the associated patient, parental, and physician anxiety.
4
The review covers approved and investigational patch pumps, proportional-integral-derivative and model-predictive-control algorithms, and anticipated next steps in closed-loop system development.
5
Tubeless patch pumps are small, lightweight, and unobtrusive, making them promising components of future artificial pancreas systems.

Insulin patch-pump systems for type 1 diabetes mellitus and their integration into closed-loop artificial pancreas systems

Patch-pump features, insulin-delivery control algorithms, and the development of automated closed-loop glucose control

Publication Details
Publication Date
2010-06-01
Journal
Publisher
ISSN
Cited by
71
Access Type
Author Information
Authors
Henry Anhalt
Nancy J.V. Bohannon
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%