Meal Simulation Model of the Glucose-Insulin System
Имитационная модель системы глюкоза–инсулин для моделирования приема пищи
2007-09-17
SCID: 54.1/fbh4jb7y
Discuss with AI
glucose fluxesglucose-insulin systemmeal simulation modeltriple tracer meal protocoltype 2 diabetes
Figures from the paper
Abstract (AI)
A simulation model of the glucose-insulin system in the postprandial state can be useful in several circumstances, including testing of glucose sensors, insulin infusion algorithms and decision support systems for diabetes. Here, we present a new simulation model in normal humans that describes the physiological events that occur after a meal, by employing the quantitative knowledge that has become available in recent years. Model parameters were set to fit the mean data of a large normal subject database that underwent a triple tracer meal protocol which provided quasi-model-independent estimates of major glucose and insulin fluxes, e.g., meal rate of appearance, endogenous glucose production, utilization of glucose, insulin secretion. By decomposing the system into subsystems, we have developed parametric models of each subsystem by using a forcing function strategy. Model results are shown in describing both a single meal and normal daily life (breakfast, lunch, dinner) in normal. The same strategy is also applied on a smaller database for extending the model to type 2 diabetes.
Key Findings
1
A forcing-function strategy was used to develop parametric models for decomposed glucose-insulin subsystems.
2
A new postprandial glucose-insulin simulation model represents physiological responses to meals in normal humans.
3
The model parameters were fitted to mean data from a large normal-subject database using a triple-tracer meal protocol.
4
The model simulates both individual meals and normal daily meal patterns, and the same strategy was extended toward type 2 diabetes.
5
Triple-tracer measurements provided quasi-model-independent estimates of meal glucose appearance, endogenous glucose production, glucose utilization, and insulin secretion.
Research Object
Meal simulation model of the human postprandial glucose–insulin system
Research Subject
physiological glucose and insulin dynamics after meals, including glucose and insulin fluxes and their variation across individual meals and normal daily eating patterns
Publication Details
Publication Date
2007-09-17
Journal
IEEE Transactions on Biomedical Engineering
Publisher
Institute of Electrical and Electronics Engineers
ISSN
0018-9294
Cited by
1098
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai1
Cited by18
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes2009
Model Predictive Control of Type 1 Diabetes: An in Silico Trial2007
GIM, Simulation Software of Meal Glucose—Insulin Model2007
Simulation Environment to Evaluate Closed-Loop Insulin Delivery Systems in Type 1 Diabetes2010
Closed-Loop Artificial Pancreas Using Subcutaneous Glucose Sensing and Insulin Delivery and a Model Predictive Control Algorithm: The Virginia Experience2009
Safety Constraints in an Artificial Pancreatic β Cell: An Implementation of Model Predictive Control with Insulin on Board2009
Closed-Loop Artificial Pancreas Using Subcutaneous Glucose Sensing and Insulin Delivery and a Model Predictive Control Algorithm: Preliminary Studies in Padova and Montpellier2009
Individualized model predictive control for the artificial pancreas: In silico evaluation of closed-loop glucose control2018
In Silico Preclinical Trials: Methodology and Engineering Guide to Closed-Loop Control in Type 1 Diabetes Mellitus2009
The Artificial Pancreas and Meal Control: An Overview of Postprandial Glucose Regulation in Type 1 Diabetes2018
An Insulin Infusion Advisory System Based on Autotuning Nonlinear Model-Predictive Control2011
Insulin Patch Pumps: Their Development and Future in Closed-Loop Systems2010
Immune-evasive beta cells in type 1 diabetes: innovations in genetic engineering, biomaterials, and computational modeling2025
An Artificial Pancreas for Automated Blood Glucose Control in Patients With Type 1 Diabetes2015
A model-based approach to synthesizing insulin infusion pump usage parameters for diabetic patients2012
Intra-patient dynamic variations in Type 1 Diabetes: A review2016
A Novel Insulin/Glucose Model after a Mixed-Meal Test in Patients with Type 1 Diabetes on Insulin Pump Therapy2016
Safe Glucose Regulation in Artificial Pancreas Systems via Robust Control Barrier Functions2025