Biosensing Dopamine and L-Epinephrine with Laccase (Trametes pubescens) Immobilized on a Gold Modified Electrode
Биосенсорное определение дофамина и L-эпинефрина с использованием лакказы (Trametes pubescens), иммобилизованной на модифицированном золотом электроде
2022-09-03
SCID: 54.1/e9dmraga
Discuss with AI
L-epinephrinechronoamperometrydopaminegold-modified electrodelaccase biosensor
Figures from the paper
Abstract (AI)
Engineering electrode surfaces through the electrodeposition of gold may provide a range of advantages in the context of biosensor development, such as greatly enhanced surface area, improved conductivity and versatile functionalization. In this work we report on the development of an electrochemical biosensor for the laccase-catalyzed assay of two catecholamines—dopamine and L-epinephrine. Variety of electrochemical techniques—cyclic voltammetry, differential pulse voltammetry, electrochemical impedance spectroscopy and constant potential amperometry have been used in its characterization. It has been demonstrated that the laccase electrode is capable of sensing dopamine using two distinct techniques—differential pulse voltammetry and constant potential amperometry, the latter being suitable for the assay of L-epinephrine as well. The biosensor response to both catecholamines, examined by constant potential chronoamperometry over the potential range from 0.2 to −0.1 V (vs. Ag|AgCl, sat KCl) showed the highest electrode sensitivity at 0 and −0.1 V. The dependencies of the current density on either catecholamine’s concentration was found to follow the Michaelis—Menten kinetics with apparent constants KMapp = 0.116 ± 0.015 mM for dopamine and KMapp = 0.245 ± 0.031 mM for L-epinephrine and linear dynamic ranges spanning up to 0.10 mM and 0.20 mM, respectively. Calculated limits of detection for both analytes were found to be within the sub-micromolar concentration range. The biosensor applicability to the assay of dopamine concentration in a pharmaceutical product was demonstrated (with recovery rates between 99% and 106%, n = 3).
Key Findings
1
A laccase (Trametes pubescens) biosensor was developed on an electrodeposited gold-modified electrode for detecting dopamine and L-epinephrine.
2
Current responses followed Michaelis–Menten kinetics, with apparent KM values of 0.116 ± 0.015 mM for dopamine and 0.245 ± 0.031 mM for L-epinephrine.
3
Dopamine quantification in a pharmaceutical product achieved recovery rates of 99%–106% (n = 3).
4
Dopamine was detected by differential pulse voltammetry and constant-potential amperometry, while amperometry also enabled L-epinephrine detection.
5
Linear dynamic ranges extended to 0.10 mM for dopamine and 0.20 mM for L-epinephrine, with sub-micromolar detection limits for both analytes.
6
The highest catecholamine sensitivity occurred at 0 and −0.1 V versus Ag|AgCl, saturated KCl, within the tested 0.2 to −0.1 V range.
Research Object
Laccase (Trametes pubescens) immobilized on a gold-modified electrode for catecholamine sensing
Research Subject
Electrochemical biosensing performance, Michaelis–Menten response, sensitivity, dynamic range, and detection limits for dopamine and L-epinephrine
Publication Details
Publication Date
2022-09-03
Journal
Publisher
ISSN
Cited by
24
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai6
Laccases: structure, function, and potential application in water bioremediation2019
Fungal laccase discovered but yet undiscovered2018
A novel Laccase Biosensor based on Laccase immobilized Graphene-Cellulose Microfiber Composite modified Screen-Printed Carbon Electrode for Sensitive Determination of Catechol2017
Bioelectrocatalysis of Oxygen Reduction Reaction by Laccase on Gold Electrodes2004
Controlling Redox Enzyme Orientation at Planar Electrodes2018
Laccase and Tyrosinase Biosensors Used in the Determination of Hydroxycinnamic Acids2021