Biosensing Dopamine and L-Epinephrine with Laccase (Trametes pubescens) Immobilized on a Gold Modified Electrode

Биосенсорное определение дофамина и L-эпинефрина с использованием лакказы (Trametes pubescens), иммобилизованной на модифицированном золотом электроде
Nina D. Dimcheva, Mariya Pimpilova, Kalina Kamarska
2022-09-03

L-epinephrinechronoamperometrydopaminegold-modified electrodelaccase biosensor
Engineering electrode surfaces through the electrodeposition of gold may provide a range of advantages in the context of biosensor development, such as greatly enhanced surface area, improved conductivity and versatile functionalization. In this work we report on the development of an electrochemical biosensor for the laccase-catalyzed assay of two catecholamines—dopamine and L-epinephrine. Variety of electrochemical techniques—cyclic voltammetry, differential pulse voltammetry, electrochemical impedance spectroscopy and constant potential amperometry have been used in its characterization. It has been demonstrated that the laccase electrode is capable of sensing dopamine using two distinct techniques—differential pulse voltammetry and constant potential amperometry, the latter being suitable for the assay of L-epinephrine as well. The biosensor response to both catecholamines, examined by constant potential chronoamperometry over the potential range from 0.2 to −0.1 V (vs. Ag|AgCl, sat KCl) showed the highest electrode sensitivity at 0 and −0.1 V. The dependencies of the current density on either catecholamine’s concentration was found to follow the Michaelis—Menten kinetics with apparent constants KMapp = 0.116 ± 0.015 mM for dopamine and KMapp = 0.245 ± 0.031 mM for L-epinephrine and linear dynamic ranges spanning up to 0.10 mM and 0.20 mM, respectively. Calculated limits of detection for both analytes were found to be within the sub-micromolar concentration range. The biosensor applicability to the assay of dopamine concentration in a pharmaceutical product was demonstrated (with recovery rates between 99% and 106%, n = 3).
1
A laccase (Trametes pubescens) biosensor was developed on an electrodeposited gold-modified electrode for detecting dopamine and L-epinephrine.
2
Current responses followed Michaelis–Menten kinetics, with apparent KM values of 0.116 ± 0.015 mM for dopamine and 0.245 ± 0.031 mM for L-epinephrine.
3
Dopamine quantification in a pharmaceutical product achieved recovery rates of 99%–106% (n = 3).
4
Dopamine was detected by differential pulse voltammetry and constant-potential amperometry, while amperometry also enabled L-epinephrine detection.
5
Linear dynamic ranges extended to 0.10 mM for dopamine and 0.20 mM for L-epinephrine, with sub-micromolar detection limits for both analytes.
6
The highest catecholamine sensitivity occurred at 0 and −0.1 V versus Ag|AgCl, saturated KCl, within the tested 0.2 to −0.1 V range.

Laccase (Trametes pubescens) immobilized on a gold-modified electrode for catecholamine sensing

Electrochemical biosensing performance, Michaelis–Menten response, sensitivity, dynamic range, and detection limits for dopamine and L-epinephrine

Publication Details
Publication Date
2022-09-03
Journal
Publisher
ISSN
Cited by
24
Access Type
Author Information
Authors
Nina D. Dimcheva
Mariya Pimpilova
Kalina Kamarska
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%